Exam 40: Quality Assessment in the Hematology Laboratory

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Moving averages can be used to monitor the instrument's performance in determining parameters of which cell line?

Free
(Multiple Choice)
4.9/5
(68)
Correct Answer:
Verified

B

What is the importance of documentation in a quality assessment program?

Free
(Essay)
4.9/5
(85)
Correct Answer:
Verified

Implementation of a quality assessment program is required by CLIA 88.A laboratory's quality assessment program should be designed to monitor all aspects related to testing patient's samples.

Patient samples are run on hematology analyzers to assess the instrument's:

Free
(Multiple Choice)
4.8/5
(83)
Correct Answer:
Verified

B

When using moving averages to monitor an automated hematology instrument, the clinical laboratory professional notes that a moving average falls out of range, but the recently performed quality control was acceptable, what would this indicate?

(Multiple Choice)
4.9/5
(74)

Given the following fibrinogen control limits: Level I x=246mg/dLs=6.0mg/dL \quad x=246 \mathrm{mg} / \mathrm{dL} \quad \mathrm{s}=6.0 \mathrm{mg} / \mathrm{dL} Level II x=75mg/dLs=2.5mg/dL \quad \mathrm{x}=75 \mathrm{mg} / \mathrm{dL} \quad \mathrm{s}=2.5 \mathrm{mg} / \mathrm{dL} If the multirule control procedure for the fibrinogen assay is 13s, 22s, and R4s, how would you interpret the fibrinogen control results for the current run? Current Run: Level I 232/ Level II 82/

(Multiple Choice)
4.8/5
(94)

What are the components of a method evaluation? Explain the purpose of each.

(Essay)
5.0/5
(92)

Which of the following is an acceptable means for competency testing?

(Multiple Choice)
4.7/5
(71)

Regarding the evaluation of proficiency testing results, which of the following sets the tolerance limit for a given hematology procedure (e.g., hemoglobin)?

(Multiple Choice)
4.8/5
(71)

Implementation of a quality assessment program in laboratories is mandated by:

(Multiple Choice)
4.9/5
(84)

What is the first step in the selection of a new instrument?

(Multiple Choice)
4.9/5
(78)

A patient's automated reticulocyte count was 203 x 10⁹/L.Which of the following could account for this result?

(Multiple Choice)
4.8/5
(76)

What is the goal of the Westgard multirule protocol for evaluating control results?

(Multiple Choice)
4.7/5
(59)

Which of the following statistical measurements can be used to analyze a new instrument's precision?

(Multiple Choice)
4.9/5
(74)

Which of the following represents an appropriate step to meet universal precautions?

(Multiple Choice)
5.0/5
(59)

The purpose of a control material is to:

(Multiple Choice)
4.9/5
(87)

Identify the critical information that must be on a material safety data sheet.

(Essay)
4.8/5
(86)

The treatment of everything in the laboratory as infectious is defined as:

(Multiple Choice)
4.9/5
(81)

A clinical laboratory professional performed a procedure to verify the hemoglobin reportable range on the Cell-Dyn 4000.The highest level of linearity check material was 22.0 g/dL.This material was run several times with 21.7 g/dL, representing the mean.How should this finding be interpreted?

(Multiple Choice)
4.8/5
(82)

Which performance study in the method evaluation process determines the reportable range for the test method?

(Multiple Choice)
4.9/5
(83)

A sample collected for a prothrombin time is delivered to the laboratory 4 hours after collection.Which source of error does this represent?

(Multiple Choice)
4.8/5
(75)