Exam 35: Automation in Hematology and Hemostasis

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

What is the main difference between the methodologies employed on the Coulter Gen-S and the Coulter LH 780?

Free
(Multiple Choice)
5.0/5
(75)
Correct Answer:
Verified

D

Which instrument does NOT use fluorescence intensity in its determination of reticulocytes?

Free
(Multiple Choice)
4.9/5
(68)
Correct Answer:
Verified

A

Explain the purpose of the following used in the standard hematologic cell counting detection methods: A)VCS flow cell B)Photodetector C)Sheath fluid D)Direct current detection block

Free
(Essay)
5.0/5
(73)
Correct Answer:
Verified

VCS flow cell: to detect each WBC's volume, conductivity, and scatter for determination of the five part differential.
Photodetector: to measure the absorbance of the unknown blood sample passing through it used in spectrophotometric detection of hgb)
Sheath fluid: Promotes hydrodynamic focusing of cells passing through photodetector.
Direct current detection block: to detect electrical resistance when cells pass through the aperture

The principle that relies on detecting resistance as cells pass through a photo-detector and is that used by most of the major hematology analyzers is:

(Multiple Choice)
4.8/5
(74)

Which technologies are used to generate the LH 750's WBC scatterplot?

(Multiple Choice)
5.0/5
(94)

Which parameter does the Coulter LH 750 instrument derive from a histogram?

(Multiple Choice)
4.9/5
(69)

Using the chromogenic methodology, a coagulation protein's activity level is related to:

(Multiple Choice)
4.9/5
(85)

Using the Fibrometer instrument, clot detection occurs when:

(Multiple Choice)
4.9/5
(84)

What is the principle of impedance? Name at least two instruments that employ this method for blood cell counting.

(Essay)
4.8/5
(83)

In the reticulocyte determination, using the Sysmex XE-2100, the fluorescent dye containing oxazine and polymethine penetrates the cell membranes and stains the blood cells.What does the oxazine bind to within the cells?

(Multiple Choice)
4.9/5
(72)

The immunologic technique available on the AMAX Destiny Plus utilizes specific reagents with:

(Multiple Choice)
4.7/5
(88)

What is the purpose of the photodetector on the Diagnostica Stago STA Compact?

(Multiple Choice)
5.0/5
(74)

Regarding the CELL-DYN Sapphire, which parameter is determined by the impedance principle?

(Multiple Choice)
4.9/5
(78)

Which of the following represents the degree of light scatter that reflects cell complexity on the CELL-DYN Sapphire?

(Multiple Choice)
5.0/5
(89)

Compare and contrast the methods of detection for the following analyzers: A)Sysmex XE-2100 B)Abbott Cell-Dyn Sapphire C)Coulter LH 780 D)Advia 2120

(Essay)
5.0/5
(61)

Which analyzer measures platelets in the same channel as reticulocytes?

(Multiple Choice)
4.9/5
(80)

Which of the following parameters are calculated on the Coulter Gen-S?

(Multiple Choice)
4.9/5
(78)

Which analyzer DOES NOT use cyanide-free detection of hemoglobin?

(Multiple Choice)
4.7/5
(75)

Which parameter does the Sysmex XE-2100 instrument determine by light scattering and fluorescence intensity characteristics?

(Multiple Choice)
4.9/5
(97)

Which of the following instruments uses both electromechanical and optical density as a means of clot detection?

(Multiple Choice)
4.8/5
(99)