Exam 38: Humidity and Bland Aerosol Therapy

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Hazards and complications of bland aerosol therapy include which of the following? 1) Bronchospasm 2) Overhydration 3) Infection 4) Hemoconcentration

Free
(Multiple Choice)
4.9/5
(88)
Correct Answer:
Verified

B

What is the goal of using an unheated bubble humidifier with oronasal O2 delivery systems?

Free
(Multiple Choice)
4.8/5
(74)
Correct Answer:
Verified

A

What is the point in the respiratory track where inspired gas reaches body temperature, ambient pressure, saturated (BTPS) conditions?

Free
(Multiple Choice)
4.8/5
(81)
Correct Answer:
Verified

D

During routine use on an intubated patient, a heated humidifier should deliver inspired gas at which of the following?

(Multiple Choice)
4.7/5
(86)

A heated humidifier should trigger both auditory and visual alarms and interrupt power to the heater when the delivered temperature exceeds which of the following?

(Multiple Choice)
4.9/5
(74)

What is the most common device used to generate bland aerosols?

(Multiple Choice)
4.7/5
(63)

Factors affecting a humidifier's performance include which of the following? 1) Surface area 2) Temperature 3) Time of contact 4) Outlet size

(Multiple Choice)
4.8/5
(85)

What device adds molecular water to gas?

(Multiple Choice)
4.9/5
(72)

Increasing the flow through an unheated bubble humidifier has which of the following effects?

(Multiple Choice)
4.7/5
(94)

Which of the following inspired conditions should be maintained when delivering medical gases directly into the trachea through an endotracheal tube or a tracheotomy tube?

(Multiple Choice)
4.9/5
(72)

When using a servo-controlled heated humidifier to deliver gas to an infant, the thermistor probe should be placed where?

(Multiple Choice)
4.9/5
(63)

Which of the following are acceptable means to help minimize the problems caused by condensation in heated humidifier circuits? 1) Installing water traps in the circuit 2) Using a heated-wire circuit 3) Setting heater temperature to 25° to 28° C

(Multiple Choice)
4.9/5
(82)

Which of the following devices would you recommend to administer bland water aerosol to an infant or small child?

(Multiple Choice)
4.8/5
(63)

An ideal heat and moisture exchanger (HME) should have an efficiency rating of at least which of the following?

(Multiple Choice)
4.8/5
(71)

Simple unheated bubble humidifiers are commonly used to humidify gases with what type of systems?

(Multiple Choice)
4.9/5
(69)

A patient has been supported by a mechanical ventilator using a heat and moisture exchanger for the last 3 days. Suctioning reveals an increase in the amount and tenacity of secretions. Which of the following actions is indicated?

(Multiple Choice)
4.9/5
(79)

A patient receiving nasal O2 at 3 L/min complains of nasal dryness and irritation. Which of the following actions would be appropriate?

(Multiple Choice)
4.9/5
(88)

To minimize problems with environmental safety when aerosol therapy is prescribed for immunosuppressed patients or those with tuberculosis, what precautions should you follow? 1) Those for tuberculosis exposure 2) Centers for Disease Control and Prevention (CDC) standards and contact precautions 3) CDC standards and airborne precautions

(Multiple Choice)
4.9/5
(78)

A physician orders bland water aerosol administration to a patient with an intact upper airway. Which of the following airway appliances could you use to meet this goal? 1) Simple O2 mask 2) Face tent 3) T tube 4) Aerosol mask

(Multiple Choice)
4.9/5
(69)

For which of the following patients would you recommend bland aerosol therapy administration? 1) Patient with a history of airway hyperresponsiveness 2) Patient with a bypassed upper airway 3) Patient with active bronchoconstriction

(Multiple Choice)
4.9/5
(72)