How are the sizes of PV system conductors and components determined?

Free
(Essay)
4.9/5
(68)
Correct Answer:
Verified

The sizes are determined by the amount of current that flows through them.

Inverter size is based on the ____ of the array.

Free
(Multiple Choice)
4.8/5
(77)
Correct Answer:
Verified

C

An inverter or ac module is required to automatically ____ its output when utility power is lost.

Free
(Multiple Choice)
4.8/5
(86)
Correct Answer:
Verified

A

A photovoltaic module is a manufactured unit made up of many semi-conductor PV cells encased in a protective covering and mounted to a(n) ____________________.

(Short Answer)
4.7/5
(79)

A combination of factors recently has made photovoltaic systems very popular including ____.

(Multiple Choice)
4.8/5
(85)

A single small inverter connected to each photovoltaic module is known as a ____-inverter.

(Multiple Choice)
5.0/5
(84)

Define anti-islanding.

(Short Answer)
4.8/5
(86)

What are buildings with stand-alone or utility-interactive PV systems required to have indicating the presence of the system and location(s) of disconnecting means?

(Essay)
4.8/5
(57)

A grounding electrode system is required for ____ photovoltaic systems.

(Multiple Choice)
4.9/5
(92)

Most residential PV systems are made up of ____ strings that can be combined in a single box.

(Multiple Choice)
4.8/5
(70)

Exposed single-conductor cable is permitted to be installed for array interconnection, and only types ____ and listed PV wire are permitted.

(Multiple Choice)
4.9/5
(79)

A connection on the ____________________ side of the main disconnect is known as a supply-side point of connection.

(Short Answer)
4.8/5
(84)

All photovoltaic modules are required by the NEC to be listed to nationally recognized standards.

(True/False)
4.8/5
(80)

According to 690.41, one conductor of a 2-wire PV system over ____________________ volts shall be grounded.

(Short Answer)
4.8/5
(96)

When determining the circuit size and current of a PV system, first use a multiplier to calculate the maximum source circuit current, then apply a second multiplier to determine the size of system conductors and ____________________.

(Short Answer)
4.8/5
(78)

A disconnect for the ungrounded dc string conductor(s) is never required before the conductors enter the dwelling.

(True/False)
4.9/5
(69)

A dedicated PV system circuit breaker, suitable for backfeed and positioned at the opposite end of the bus from the ____, is a requirement of NEC 705.12(B).

(Multiple Choice)
4.8/5
(84)

Photovoltaic modules that also serve as an outer protective finish for a building are known as structure-integrated photovoltaic (SIPV) modules.

(True/False)
4.9/5
(75)

NEC 690.7(C) limits photovoltaic source and output circuits to 600 volts or less for one- and two-family dwellings.

(True/False)
4.9/5
(85)

If circuit conductors for PV systems were sized using the requirements of 690.8(B) and there are no external sources of parallel currents that exceed the ampacity of the conductors, then overcurrent protection is required.

(True/False)
4.9/5
(87)