Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

NEC 422.16(B)(4) permits a range hood to be cord-and-plug connected. The receptacle would be installed ____ the range.

Free
(Multiple Choice)
4.9/5
(67)
Correct Answer:
Verified

B

A single receptacle on a 20-ampere individual branch circuit must be rated ____________________.

Free
(Short Answer)
4.8/5
(87)
Correct Answer:
Verified

20 amperes
20 ampere

What piece of kitchen equipment is permitted to be connected to the two 20-ampere small-appliance circuits required for the kitchen and dining room area?

Free
(Multiple Choice)
4.7/5
(86)
Correct Answer:
Verified

C

When installing a multiwire branch circuit, a means must be provided to simultaneously disconnect all of the hot conductors at the panelboard where the circuit originates. This means is normally a(n) ____________________.

(Short Answer)
5.0/5
(76)

When an individual branch circuit is run for the refrigerator, some inspectors require that a single receptacle be installed to "meet Code." A single receptacle ensures that the receptacle will not supply other appliances, although this is highly unlikely since the receptacle is ____________________ the refrigerator.

(Short Answer)
4.8/5
(69)

The receptacle for a kitchen refrigerator is permitted to be supplied by a(n) ____________________ branch circuit.

(Short Answer)
4.7/5
(84)

A(n) ____ receptacle can be hidden behind a painting or photograph that you want to light up.

(Multiple Choice)
4.8/5
(80)

When a luminaire is connected to the conductors, the outlet is referred to as a ____ outlet.

(Multiple Choice)
4.9/5
(87)

Kitchen lighting ____ permitted to be supplied by the two 20-ampere small-appliance circuits required for the kitchen and dining room area.

(Multiple Choice)
4.8/5
(74)

Because of the dangers associated with the open neutral (grounded conductor), NEC 300.13(B) does not permit the continuity of the ____ conductor to depend on a receptacle.

(Multiple Choice)
4.9/5
(66)

A 125-volt, 15- and 20-ampere receptacle installed to serve a kitchen countertop is required ____.

(Multiple Choice)
5.0/5
(84)

Countertop receptacles must be served by at least ____-ampere small appliance circuits.

(Multiple Choice)
4.8/5
(87)

A popular use of ____________________ is to control one receptacle with a switch and leave one receptacle "hot" at all times.

(Short Answer)
4.9/5
(89)

The load for each small-appliance, branch circuit load is required to be calculated at ____.

(Multiple Choice)
4.9/5
(89)

The sound level rating used to define fan noise is expressed in ____.

(Multiple Choice)
4.9/5
(79)

The 125-volt, 20-ampere receptacles installed to serve kitchen countertops are required to have GFCI protection ____.

(Multiple Choice)
4.9/5
(82)

Cord-and-plug-connected appliances shall not exceed ____ percent of the branch-circuit rating.

(Multiple Choice)
4.8/5
(79)

Most duplex receptacles can be changed into "split-wired" receptacles by ____.

(Multiple Choice)
5.0/5
(81)

GFCI protection can be provided for convenience receptacles serving kitchen countertop areas by ____.

(Multiple Choice)
5.0/5
(91)

The NEC defines a kitchen as an area with a sink and ____ provisions for food preparation and cooking.

(Multiple Choice)
4.9/5
(81)