Exam 8: Lighting Branch Circuit for the Front Bedroom

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

What is wall washing?

Free
(Essay)
4.8/5
(69)
Correct Answer:
Verified

The term wall washing is used when luminaires are installed in a row, parallel to the wall that is to be "washed" with light.

Electric baseboard heaters may not be permitted to be installed ____________________ a receptacle outlet.

Free
(Short Answer)
4.9/5
(76)
Correct Answer:
Verified

below
beneath
under
underneath

Explain why the required minimum clearances for fluorescent fixtures installed in closets are smaller than those for incandescent fixtures.

Free
(Essay)
4.9/5
(93)
Correct Answer:
Verified

Incandescent fixtures develop higher surface temperatures than fluorescent fixtures and therefore represent a greater fire danger in closets filled with flammable goods.

A(n) ____________________ is used only to ground the metal box and must never be used as a current-carrying conductor.

(Short Answer)
4.8/5
(71)

Calculate the volt-amperes and watts of a 120-volt, 10-ampere motor at 50 percent power factor.

(Essay)
4.9/5
(64)

An outside weatherproof outlet is required to have ____________________ protection.

(Short Answer)
4.7/5
(87)

The NEC allows what maximum number of receptacle outlets to be connected on a 120-volt residential lighting or small-appliance branch circuit?

(Multiple Choice)
4.8/5
(84)

Explain why pigtails used to connect receptacles to branch-circuit wiring need not be counted when determining the correct outlet box size.

(Essay)
5.0/5
(74)

NEC 210.11(B) requires that load be evenly proportioned among the different circuits in a panelboard. This is normally performed at the load center panelboard by connecting branch-circuit wiring so that the connected load on the two ____________________ is as equal as possible.

(Short Answer)
4.9/5
(70)

Which switch type is rarely used in residential wiring?

(Multiple Choice)
5.0/5
(78)

How many lighting outlets are permitted on one branch circuit?

(Multiple Choice)
4.9/5
(75)

Residential wiring plans generally show lighting and receptacle outlet locations but not circuits. The electrician should design the installation with which of the following in mind?

(Multiple Choice)
5.0/5
(88)

What kind of receptacle outlet has a top portion that is "hot" at all times and a bottom portion that is controlled by the wall switch?

(Essay)
4.8/5
(79)

To be effective, accent lighting should be at least ____ times that of the surrounding general lighting.

(Multiple Choice)
4.8/5
(76)

What is the NEC definition of a clothes closet?

(Essay)
4.8/5
(78)

What Code section provides very specific rules for the location and types of luminaires permitted to be installed in clothes closets?

(Short Answer)
4.8/5
(93)

Which rule of thumb can be followed when planning branch circuits for dwelling units?

(Multiple Choice)
4.8/5
(79)

When using nonmetallic boxes, the equipment grounding conductor in nonmetallic-sheathed cable is connected to the ____-shaped equipment grounding screw found on all switches and receptacles.

(Multiple Choice)
4.9/5
(88)

Many electricians wire the lights and receptacles in a room on different circuits because this ____.

(Multiple Choice)
4.8/5
(84)

Receptacles installed on 15- and 20-ampere branch circuits must be of the ____ type.

(Multiple Choice)
4.8/5
(87)
Showing 1 - 20 of 22
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)