Exam 19: Special-Purpose Outletswater Pump, Water Heater
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
Submersible pump cable supplied with well pump assemblies ____ also suitable for direct burial.
Free
(Multiple Choice)
4.9/5
(74)
Correct Answer:
B
NEC 430.103 requires that a disconnecting means for a motor shall ____ ungrounded conductors.
Free
(Multiple Choice)
4.7/5
(83)
Correct Answer:
A
The overload protection for a motor might be thermal overloads (sometimes called ____________________) in the controller, electronic sensing overload devices, built-in thermal protection, or time-delay fuses.
Free
(Short Answer)
4.7/5
(85)
Correct Answer:
heaters
Article 430 contains requirements for motor installations. The section that requires a motor disconnect to be within sight of the motor or capable of being locked is ____________________.
(Short Answer)
4.9/5
(72)
Briefly explain what is meant by the electric utility program known by all of the following names: "time of day," "time of use," and "off-peak."
(Essay)
4.8/5
(71)
Where the values of branch-circuit protection required for motors according to Table 430.52 do not correspond to standard ratings as listed in NEC 240.6, the next ____ rating is permitted to be used.
(Multiple Choice)
4.9/5
(89)
Most installations require motor overload protection not to exceed ____________________ of the motor's full-load current rating.
(Short Answer)
4.9/5
(81)
Should it be required to run a pump's circuit underground for any distance, it is necessary to install Type UF or Type USE cable or ____, and then make up the necessary splices in a listed weatherproof junction box
(Multiple Choice)
4.9/5
(87)
Explain why heating elements in water heaters are frequently rated 250 volts for operation on 240-volt circuits.
(Essay)
4.8/5
(73)
UL requires that the power (wattage) input must not exceed ____ percent of the water heater's nameplate rating.
(Multiple Choice)
4.8/5
(71)
Because a water heater represents a continuous load, the branch circuit must be rated not less than ____ percent of the water heater nameplate rating.
(Multiple Choice)
4.8/5
(79)
An individual motor disconnect must be in sight of the motor controller and must disconnect the controller. The NEC definition of in sight means that the controller must be visible and not more than ____ from the disconnect.
(Multiple Choice)
4.9/5
(90)
A disconnect need not be in sight of motor and driven machinery if the disconnect can be ____________________ in the open "OFF" position.
(Short Answer)
4.8/5
(77)
According to NEC 230.7, conductors other than service-entrance conductors are not permitted in the same raceway as the service-entrance conductors. However, what does Exception No. 2 permit?
(Essay)
4.8/5
(67)
When a non-motor-operated electrical appliance is not marked with its overcurrent protective device rating, NEC 422.11(E) states that the branch circuit overcurrent protection shall be ____.
(Multiple Choice)
5.0/5
(73)
The Code requirements for standard resistance-type electric water heaters are found in Article 422. Because heat pump water heaters contain a hermetic refrigerant motor compressor, their Code requirements are found in Article ____________________.
(Short Answer)
4.9/5
(79)
Water pumps that contain all required starting and protection components and connect directly to the pressure switch with no above-ground controller, are often called ____________________ pumps.
(Short Answer)
4.7/5
(85)
The NEC permits overcurrent protective devices for individual branch circuits to appliances to be sized up to 150 percent of the appliance ampere rating. However, if the 150 percent sizing does not correspond to a standard size fuse or circuit-breaker, then what size is permitted?
(Short Answer)
4.8/5
(99)
If a 115/230-volt, dual-voltage motor has a full-load current of 8 amperes at 230 volts, the same motor connected for 115-volt operation will draw ____________________ amperes.
(Short Answer)
4.9/5
(75)