Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
Wall receptacles in a habitable room must be placed so they are no further than ____ feet from any point along the wall.
Free
(Multiple Choice)
4.7/5
(81)
Correct Answer:
C
The NEC defines a ____ as "the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s)."
Free
(Multiple Choice)
4.8/5
(85)
Correct Answer:
B
The Code specifies which rooms in a dwelling are required to have switched lighting outlets or switched receptacles. Choose yes (switch required) or no (switch not required) for the following areas:
-Crawl space (contains equipment that requires servicing)
Free
(Multiple Choice)
4.8/5
(84)
Correct Answer:
A
A continuous load shall not exceed ____ percent of the rating of the branch circuit.
(Multiple Choice)
4.8/5
(82)
The general lighting load for a dwelling is based on the ____.
(Multiple Choice)
4.8/5
(85)
In construction of one- and two-family dwellings, the electrical circuits are usually designed by the ____.
(Multiple Choice)
4.9/5
(80)
The minimum lighting load requirement for dwelling units is ____ volt-amperes per square ft (0.093 m3).
(Multiple Choice)
4.9/5
(77)
The Code specifies which rooms in a dwelling are required to have switched lighting outlets or switched receptacles. Choose yes (switch required) or no (switch not required) for the following areas:
-Bathroom
(Multiple Choice)
4.8/5
(58)
Calculate the minimum number of 15-ampere lighting branch circuits required in a residence of 1,850 square feet.
(Essay)
4.8/5
(85)
With the exception of ____, the 20-ampere appliance circuits required by NEC are permitted to serve no other loads.
(Multiple Choice)
4.9/5
(84)
Most public service commissions require that the voltage for residential services be held to ± ____ percent of the nominal voltage as measured at the service point.
(Multiple Choice)
4.9/5
(74)
For continuous loads, the branch-circuit rating, the conductors, and the overcurrent device shall not be less than ____ percent of the rating of the equipment.
(Multiple Choice)
4.8/5
(97)
The Code specifies which rooms in a dwelling are required to have switched lighting outlets or switched receptacles. Choose yes (switch required) or no (switch not required) for the following areas:
-Attic (not intended for storage)
(Multiple Choice)
4.7/5
(67)
Where there are _________________________ or more on an interior stairway, a wall-switch control of the stairway lighting must be provided on each floor level and any level that has an entryway.
(Short Answer)
4.8/5
(80)
Receptacles in unfinished basements must be ____________________ protected.
(Short Answer)
4.7/5
(75)
Showing 1 - 20 of 26