Exam 32: Standby Power Systems
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
What must a transfer switch must do in such a way that there is no feedback from the generator to the utility system?
Free
(Essay)
4.8/5
(60)
Correct Answer:
The transfer switch must isolate the utility source from the standby source.
The term separately derived system as defined in NEC Article 100 means that the transfer equipment must break all system conductors from the generator, including the neutral.
Free
(True/False)
4.9/5
(80)
Correct Answer:
True
NEC 590.6(A)(3) requires that all 125 volt and 125/250 volt, single-phase, 15-, 20-, and 30 ampere receptacle outlets that are a part of a ____ kW or smaller portable generator shall have listed groundfault circuit interrupter protection for personnel.
Free
(Multiple Choice)
4.8/5
(88)
Correct Answer:
B
Because generators produce a certain level of ____________________ when running, you will want to check with your building authorities to make sure the generator you choose is in compliance with local codes that might be applicable.
(Short Answer)
4.9/5
(73)
Where the normal power main service disconnecting means is located inside of the home, some electrical inspectors will require that a disconnect for the standby power from the generator be installed near the back door of the home.
(True/False)
4.7/5
(78)
Standby power conductors and normal power conductors must not be run in the same raceway or enclosure.
(True/False)
4.8/5
(82)
If a homeowner has a generator without GFCI protection, a listed ____________________ that has GFCI protection may be used.
(Short Answer)
4.8/5
(84)
For home installations, transfer switches may be ____________________ or double-pole, double throw (DPDT), depending on how the type of system is being installed.
(Short Answer)
4.7/5
(78)
The conductors that run from the standby generator to the transfer switch and to the generator panelboard that contains the branch-circuit overcurrent devices shall be sized not less than ____ percent of the generator's nameplate current rating.
(Multiple Choice)
4.8/5
(70)
How must a transfer switch connected to the line side of the main service disconnect be listed?
(Essay)
4.8/5
(87)
A transfer switch shifts power from the normal utility source to the ____________________.
(Short Answer)
4.9/5
(84)
Actual wiring of a typical standby generator consists of ____ ungrounded conductor(s) and one grounded "neutral" conductor.
(Multiple Choice)
4.9/5
(78)
The generator for a standby power system is permanently installed on a concrete pad at a suitable location outside of the home.
(True/False)
4.9/5
(87)
Which loads in a house are homeowners typically concerned about continuing to have power in the event of a power outage?
(Essay)
4.7/5
(73)
Generators for home use are generally rated in ____________________.
(Short Answer)
4.8/5
(81)