Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
Switches must be at least ____ ft. from the inside wall of a spa or hot tub.
Free
(Multiple Choice)
4.8/5
(75)
Correct Answer:
B
A clearly labeled emergency shutoff switch for the control of the recirculation system and jet system for spas and hot tubs must be installed at a point readily accessible to the users and not less than ____________________ away and within sight of the spa or hot tub.
Free
(Short Answer)
4.9/5
(87)
Correct Answer:
5 ft
5'
1.5 m
Drownings have occurred when a person is trapped under water by the tremendous ____ at an unprotected drain in a swimming pool.
Free
(Multiple Choice)
5.0/5
(80)
Correct Answer:
A
Do not bond together metal raceways, metal piping, and other metal surfaces within 5 ft (1.5 m) of the inside walls of the spa or hot tub, unless separated by a permanent barrier, such as a wall or building.
(True/False)
4.9/5
(72)
We are permitted to use a flexible cord-and-plug connection for fixed or stationary equipment associated with a permanently installed pool. Underwater luminaires are included in this permission.
(True/False)
4.8/5
(90)
At least one 125-volt, 15- or 20-amp GFCI-protected receptacle must be installed no closer than ____________________ ft but not farther than 10 ft from the inside wall of a spa or hot tub.
(Short Answer)
4.9/5
(72)
Where there are no metal parts in contact with pool water, there still is a need to bond the water to the pool deck to eliminate voltage gradients between the pool water and the deck.
(True/False)
4.9/5
(75)
Where there are no metal parts in contact with pool water, there still is a need to bond the water to the pool deck to eliminate voltage gradients between the pool water and the deck.
(True/False)
4.9/5
(87)
Switches must be at least ____ ft. from the inside wall of a spa or hot tub.
(Multiple Choice)
4.8/5
(82)
A hydromassage bathtub constitutes more of a shock hazard than a regular bathtub.
(True/False)
4.9/5
(75)
A receptacle that supplies power to a spa or hot tub must be ____.
(Multiple Choice)
4.9/5
(89)
At least one 125-volt, 15- or 20-amp GFCI-protected receptacle must be installed no closer than ____________________ ft but not farther than 10 ft from the inside wall of a spa or hot tub.
(Short Answer)
4.8/5
(78)
UL Standard 1563 establishes the maximum water temperature at 104 degrees F, and the suggested maximum time of immersion is generally ____________________ minutes.
(Short Answer)
4.8/5
(77)
The branch-circuit conductor ampacity and the rating of the branch-circuit overcurrent devices must not be less than ____ percent of the total nameplate rated-load ampere rating of an electric pool water heater.
(Multiple Choice)
4.8/5
(81)
The purpose of bonding together all metal parts and other conductive surfaces that are part of, in, and around a permanently installed swimming pool is to ____ voltage gradients in the pool and adjacent areas around the pool.
(Multiple Choice)
4.8/5
(82)
Once you run conductors beyond (on the load side of) a GFCI device protecting that wiring, you are not permitted to have other conductors in the same raceway, box, or enclosure. Give two exceptions to this rule.
(Essay)
4.9/5
(76)
A self-contained spa or hot tub assembly may be connected using a wiring method that contains a copper equipment-grounding conductor not smaller than ____ AWG.
(Multiple Choice)
4.9/5
(80)
The purpose of bonding together all metal parts and other conductive surfaces that are part of, in, and around a permanently installed swimming pool is to ____ voltage gradients in the pool and adjacent areas around the pool.
(Multiple Choice)
4.8/5
(89)
The branch-circuit conductor ampacity and the rating of the branch-circuit overcurrent devices must not be less than ____ percent of the total nameplate rated-load ampere rating of an electric pool water heater.
(Multiple Choice)
4.7/5
(81)
Drownings have occurred when a person is trapped under water by the tremendous ____ at an unprotected drain in a swimming pool.
(Multiple Choice)
5.0/5
(81)
Showing 1 - 20 of 38
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)