Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
Some additional rules apply when nonmetallic-sheathed cable and armored cable are ____, because of possible physical damage to the cables.
Free
(Multiple Choice)
4.7/5
(77)
Correct Answer:
A
To ensure that the conductor insulation will not be injured, be sure to ream the cut ends of rigid conduit and electrical metallic tubing to remove ____.
Free
(Multiple Choice)
4.9/5
(79)
Correct Answer:
D
What Code section makes it mandatory to install at least one receptacle outlet in each unfinished basement area?
Free
(Short Answer)
4.9/5
(90)
Correct Answer:
NEC 210.52(G)
210.52(G)
When metal raceways are used in house construction, in most cases the type of raceway will be ____________________.
(Short Answer)
4.8/5
(71)
When transitions between cable and conduit must be made, usually this will be a(n) ____________________.
(Short Answer)
4.8/5
(80)
Raceways ____ required be installed as a complete system between pull points before pulling in the wires.
(Multiple Choice)
4.9/5
(76)
The circuit feeding the required laundry area receptacle(s) shall have ____ outlets connected to it.
(Multiple Choice)
4.7/5
(64)
When a single receptacle of any rating is installed on an individual branch circuit, the receptacle rating must not be ____ than the rating of the branch circuit.
(Multiple Choice)
4.8/5
(75)
In many parts of the country, the wiring method in unfinished basements is ____ in the ceiling and EMT on the walls for receptacles and switches.
(Multiple Choice)
4.9/5
(83)
The NEC fill calculations for a conduit nipple not over 24 in. (600 mm) allows what fill percentage for three or more conductors?
(Multiple Choice)
4.8/5
(79)
When a nonmetallic wiring method is installed where short sections of metal raceway are provided for mechanical protection-or for appearance-these short sections of raceway ____ be grounded.
(Multiple Choice)
4.8/5
(78)
The derating factor that must be used when four to six current-carrying conductors are installed in a conduit is ____ percent.
(Multiple Choice)
5.0/5
(77)
The NEC requires that all 125-volt, ____, 15- or 20-ampere receptacles installed in unfinished basements must be GFCI protected.
(Multiple Choice)
4.9/5
(75)
Many electrical ordinances require that a separate equipment grounding conductor be installed in all raceways, whether rigid or flexible, whether ____________________.
(Short Answer)
4.8/5
(84)
For the typical ____________________, the duplex receptacle would be fastened to it by two small No. 6-32 bolts and nuts.
(Short Answer)
4.8/5
(80)
The advantage(s) of pull-chain switches for lighting fixtures include ____.
(Multiple Choice)
4.9/5
(83)
A(n) ____________________ conductor carrying the unbalanced currents from the other conductors need not be counted when determining the ampacity of the conductor, according to NEC 310.15(B)(5)(a).
(Short Answer)
4.8/5
(83)
The branch circuit feeding the required laundry receptacle ____ permitted to supply other dedicated equipment in the laundry room, including lighting and an exhaust fan.
(Multiple Choice)
4.8/5
(70)
Many workshop fluorescent luminaires are furnished with a 3-wire (____) flexible cord suitable for the purpose that has the attachment plug cap factory-attached to the cord.
(Multiple Choice)
4.7/5
(80)