Exam 27: Service-Entrance Equipment
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
NEC 300.4(F) states that if ____ AWG or larger ungrounded circuit conductors enter a cabinet, box enclosure or raceway, an insulating bushing or equivalent must be used.
Free
(Multiple Choice)
4.9/5
(84)
Correct Answer:
A
Ground rods must be at least ____ ft. in length
Free
(Multiple Choice)
4.7/5
(73)
Correct Answer:
B
When using a metal water pipe as a grounding electrode, a(n) ____________________ is required.
Free
(Short Answer)
4.9/5
(74)
Correct Answer:
supplemental electrode
NEC ____________________ provides rules for working space around electrical equipment.
(Short Answer)
4.8/5
(77)
____________________ conductors are permitted to be attached to and supported by the service mast.
(Short Answer)
4.8/5
(68)
It is extremely important that a disconnect or panelboard used as service equipment be marked "____________________."
(Short Answer)
4.8/5
(82)
A panelboard must not be installed in a(n) ____________________.
(Short Answer)
4.8/5
(83)
A 4 AWG bare copper conductor at least 20 ft (6.0 m) long installed identically to the steel reinforcing rod is also permitted as a concrete-encased grounding electrode. This is often referred to as a(n) ____________________ ground.
(Short Answer)
4.8/5
(81)
A main service disconnect shall not be installed in a ____.
(Multiple Choice)
4.8/5
(79)
A working space not less than ____ in. wide and 3 ft deep must be provided in front of electrical equipment, such as panelboards A and B in this residence.
(Multiple Choice)
4.9/5
(66)
Bonding at service-entrance equipment is very important because service-entrance conductors do not have ____________________ at their line side, other than the electric utility company's primary transformer fuses.
(Short Answer)
4.8/5
(77)
For a one-family residence, the minimum size main service disconnecting means is ____ three-wire.
(Multiple Choice)
4.8/5
(86)
Using an electric rate of $0.07824 per kWh, calculate the cost of running ten 100W lamps for six hours.
(Essay)
4.7/5
(76)
If extra support is not to be provided, the mast service conduit must be at least ____ in. in diameter.
(Multiple Choice)
4.8/5
(83)
For typical residential wiring, the grounding electrode conductor is run between the ____________________ neutral/ground terminal bar and the grounding electrode system.
(Short Answer)
4.8/5
(76)
An exterior raceway containing service entrance conductors must be ____________________ and arranged to drain.
(Short Answer)
4.8/5
(81)
Under no circumstances shall the service entrance conductors be less than ____ ft. above finished grade.
(Multiple Choice)
4.7/5
(89)