Exam 2: Electrical Symbols and Outlets
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
Name several factors that must be taken into account when sizing boxes per the NEC.
Free
(Essay)
4.8/5
(94)
Correct Answer:
Factors include devices installed, circuit wires, hickeys and studs, clamps, and equipment grounding conductors.
Unused knockouts in boxes, spaces for ____________________ in a panel, meter socket enclosures, and all other similar equipment must be effectively closed.
Free
(Short Answer)
5.0/5
(79)
Correct Answer:
circuit breakers
Device faceplates must be mounted so as to ____.
Free
(Multiple Choice)
4.7/5
(83)
Correct Answer:
D
According to ____, unused knockouts and other openings in electrical boxes and cabinets are required to be closed.
(Multiple Choice)
4.9/5
(86)
Match the following switch types with their drawing symbols.
-Three-way
(Multiple Choice)
4.7/5
(74)
The NEC requires that a(n) ____ be installed at each conductor splice connection point.
(Multiple Choice)
5.0/5
(80)
When doing ____________________ work, requirements for supporting and securing cables are relaxed so that the cables can be "fished" through the existing wall construction.
(Short Answer)
4.9/5
(81)
In walls or ceilings constructed of noncombustible material, such as concrete or tile, the edge of the outlet box is permitted to be set back not more than ____________________ from the finished surface.
(Short Answer)
5.0/5
(90)
Where noncombustible surface material is used on walls or ceilings, outlet boxes must be mounted so that they will be set back not more than ____ from the face of the surface material.
(Multiple Choice)
4.7/5
(70)
Device boxes are designed for size No. ____________________ screws.
(Short Answer)
4.9/5
(93)
Match the following switch types with their drawing symbols.
-Dimmer switch
(Multiple Choice)
4.7/5
(82)
Explain the requirements for installing a lighting fixture weighing more than fifty pounds.
(Essay)
4.9/5
(78)
In order that the connections inside an outlet box remain accessible, the NEC requires that a surface extension from an outlet box cover be made using ____.
(Multiple Choice)
5.0/5
(78)
Lighting outlet boxes are designed for size No. ____________________ screws.
(Short Answer)
4.8/5
(87)
Match the following switch types with their drawing symbols.
-Single-pole
(Multiple Choice)
4.8/5
(83)
Electrical wall boxes should not be mounted back-to-back in walls because ____.
(Multiple Choice)
4.9/5
(84)
Showing 1 - 20 of 24
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)