Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
Name at least four kinds of lighting switches.
Free
(Essay)
4.8/5
(78)
Correct Answer:
Lighting switches include single-pole, three-way, four-way, double-pole, pilot light, dimmer, snap, push, rocker, rotary, and slider.
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
-Brass-colored screw
Free
(Multiple Choice)
4.8/5
(81)
Correct Answer:
B
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
-10 AWG copper
Free
(Multiple Choice)
4.8/5
(83)
Correct Answer:
C
On isolated ground receptacles, the metal yoke ____ integrally bonded to the equipment grounding terminal of the receptacle.
(Multiple Choice)
4.8/5
(75)
Alternating current, general-use snap switches are UL-listed to control motors rated up to ____ horsepower.
(Multiple Choice)
5.0/5
(75)
When receptacles or switches have No. 6-32 screws secured to them with small pieces of cardboard, these pieces of cardboard must be ____ when the wiring device is installed in a metal outlet box.
(Multiple Choice)
4.9/5
(71)
When using individual conductors in raceway, which insulation color is NOT permitted for the grounded conductor (neutral)?
(Multiple Choice)
4.8/5
(69)
A 4-way switch does not have "ON" and "OFF" markings. Four-way switches are connected to the "____________________" between two 3-way switches. One 3-way switch is fed by the ____________________; the other 3-way switch is connected to the load.
(Short Answer)
4.7/5
(76)
All 125-volt, 15- and 20-ampere receptacles in a dwelling are required to be ____.
(Multiple Choice)
4.8/5
(82)
Screwless push-in terminals (i.e., back wiring holes) on receptacles are listed only for use with what type of branch-circuit conductor?
(Essay)
4.8/5
(80)
Snap switches with nonmetallic yokes (straps) have a terminal for the equipment grounding conductor. Using this type of switch provides a means for grounding ____ faceplates when nonmetallic boxes are used.
(Multiple Choice)
4.9/5
(78)
The long slot on a 15-ampere, 125-volt, receptacle is the ____ conductor.
(Multiple Choice)
4.9/5
(83)
The conductors that run between a switched outlet and the switch controlling the outlet are called a(n) ____________________.
(Short Answer)
4.8/5
(71)
Match the following switch types with the correct number of terminals for each.
-Four-way switch
(Multiple Choice)
4.8/5
(86)
The common point on a wye-connected polyphase system or the mid-point on a single phase system is the _________________________.
(Short Answer)
4.7/5
(90)
Match the following switch types with the correct number of terminals for each.
-Single-pole switch
(Multiple Choice)
4.9/5
(63)
To avoid inductive heating in metallic raceways, the NEC requires that ____.
(Multiple Choice)
4.9/5
(62)
Describe what NEC 250.148 requires to maintain the continuity of the equipment grounding path.
(Essay)
5.0/5
(71)
Showing 1 - 20 of 31
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)