Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

Name at least four kinds of lighting switches.

Free
(Essay)
4.8/5
(78)
Correct Answer:
Verified

Lighting switches include single-pole, three-way, four-way, double-pole, pilot light, dimmer, snap, push, rocker, rotary, and slider.

Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor. -Brass-colored screw

Free
(Multiple Choice)
4.8/5
(81)
Correct Answer:
Verified

B

Specify the maximum overcurrent protection permitted for following the circuit conductor sizes: -10 AWG copper

Free
(Multiple Choice)
4.8/5
(83)
Correct Answer:
Verified

C

On isolated ground receptacles, the metal yoke ____ integrally bonded to the equipment grounding terminal of the receptacle.

(Multiple Choice)
4.8/5
(75)

Alternating current, general-use snap switches are UL-listed to control motors rated up to ____ horsepower.

(Multiple Choice)
5.0/5
(75)

When receptacles or switches have No. 6-32 screws secured to them with small pieces of cardboard, these pieces of cardboard must be ____ when the wiring device is installed in a metal outlet box.

(Multiple Choice)
4.9/5
(71)

When is a reidentified white conductor NOT permitted?

(Essay)
4.9/5
(75)

When using individual conductors in raceway, which insulation color is NOT permitted for the grounded conductor (neutral)?

(Multiple Choice)
4.8/5
(69)

A 4-way switch does not have "ON" and "OFF" markings. Four-way switches are connected to the "____________________" between two 3-way switches. One 3-way switch is fed by the ____________________; the other 3-way switch is connected to the load.

(Short Answer)
4.7/5
(76)

All 125-volt, 15- and 20-ampere receptacles in a dwelling are required to be ____.

(Multiple Choice)
4.8/5
(82)

Screwless push-in terminals (i.e., back wiring holes) on receptacles are listed only for use with what type of branch-circuit conductor?

(Essay)
4.8/5
(80)

Snap switches with nonmetallic yokes (straps) have a terminal for the equipment grounding conductor. Using this type of switch provides a means for grounding ____ faceplates when nonmetallic boxes are used.

(Multiple Choice)
4.9/5
(78)

The long slot on a 15-ampere, 125-volt, receptacle is the ____ conductor.

(Multiple Choice)
4.9/5
(83)

The conductors that run between a switched outlet and the switch controlling the outlet are called a(n) ____________________.

(Short Answer)
4.8/5
(71)

Match the following switch types with the correct number of terminals for each. -Four-way switch

(Multiple Choice)
4.8/5
(86)

"T"-rated snap switches are intended for what application?

(Essay)
4.7/5
(87)

The common point on a wye-connected polyphase system or the mid-point on a single phase system is the _________________________.

(Short Answer)
4.7/5
(90)

Match the following switch types with the correct number of terminals for each. -Single-pole switch

(Multiple Choice)
4.9/5
(63)

To avoid inductive heating in metallic raceways, the NEC requires that ____.

(Multiple Choice)
4.9/5
(62)

Describe what NEC 250.148 requires to maintain the continuity of the equipment grounding path.

(Essay)
5.0/5
(71)
Showing 1 - 20 of 31
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)