Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems
Exam 1: General Information for Electrical Installations18 Questions
Exam 2: Electrical Symbols and Outlets24 Questions
Exam 3: Determining the Required Number of Branch Circuits, Lighting Outlets, Receptacle Outlets26 Questions
Exam 4: Conductor Sizes and Types, Wiring Methods, Wire Connections, Voltage Drop, Neutral Conductor Sizing for Services39 Questions
Exam 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating31 Questions
Exam 6: Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and Appliance Leakage Current Interrupters23 Questions
Exam 7: Luminaires, Ballasts, and Lamps33 Questions
Exam 8: Lighting Branch Circuit for the Front Bedroom22 Questions
Exam 9: Lighting Branch Circuit for the Master Bedroom20 Questions
Exam 10: Lighting Branch Circuitbathrooms, Hallway20 Questions
Exam 11: Lighting Branch Circuit-Front Entry, Porch, Post-Light, Underground Wiring13 Questions
Exam 12: Lighting Branch Circuit and Small-Appliance Circuits for the Kitchen20 Questions
Exam 13: Lighting Branch Circuit for the Living Room16 Questions
Exam 14: Lighting Branch Circuit for the Studybedroom7 Questions
Exam 15: Dryer Outlet, Lighting and Receptacle Circuits for the Laundry, Powder Room, Rear Entry Hall, and Attic19 Questions
Exam 16: Branch Circuits for the Garage and Outdoors20 Questions
Exam 17: Recreation Room14 Questions
Exam 18: Lighting Branch Circuit, Receptacle Circuits for Workshop21 Questions
Exam 19: Special-Purpose Outletswater Pump, Water Heater21 Questions
Exam 20: Special-Purpose Outlets for Ranges, Counter-Mounted Cooking Unit G, and Wall-Mounted Oven F24 Questions
Exam 21: Special-Purpose Outletsfood Waste Disposer, Dishwasher16 Questions
Exam 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a18 Questions
Exam 23: Special-Purpose Outletselectric Heating, Air Conditioning27 Questions
Exam 24: Gas and Oil Central Heating Systems20 Questions
Exam 25: Television, Telephone, and Low-Voltage Signal Systems20 Questions
Exam 26: Smoke, Heat, and Carbon Monoxide Alarms, and Security Systems20 Questions
Exam 27: Service-Entrance Equipment20 Questions
Exam 28: Overcurrent Protectionfuses and Circuit Breakers20 Questions
Exam 29: Service-Entrance Calculations17 Questions
Exam 30: Swimming Pools, Spas, Hot Tubs, and Hydromassage Baths38 Questions
Exam 31: Wiring for the Future: Home Automation Systems20 Questions
Exam 32: Standby Power Systems15 Questions
Exam 33: Residential Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
In the event of a(n) ____________________, an ac-dc smoke alarm continues to operate on the battery.
Free
(Short Answer)
4.9/5
(80)
Correct Answer:
power outage
Plug-in detectors are not permitted in new construction.
Free
(True/False)
4.8/5
(77)
Correct Answer:
True
According to NFPA 72, fire warning equipment has two primary purposes: to provide protection to property, and to provide a reliable means to notify the occupants of the presence of a threatening fire and the need to escape to a place of safety.
Free
(True/False)
5.0/5
(84)
Correct Answer:
False
____________________ conductors in cable must be a minimum of 26 AWG.
(Short Answer)
4.7/5
(61)
In new residential construction smoke alarms must be installed in all ____________________ rooms and outside the ____________________ area, and on each floor.
(Short Answer)
4.8/5
(80)
NFPA 72 29.1.2 states that smoke and heat alarms shall be installed in all occupancies where required by governing laws, codes, or standards. This puts the responsibility on the local building department.
(True/False)
4.9/5
(82)
____________________ may or may not accept wireless smoke alarm systems.
(Short Answer)
4.9/5
(87)
Fire-protective signaling systems installed in homes have ____ circuits where the power output is limited by the listed power supply for the system.
(Multiple Choice)
4.8/5
(83)
Smoke alarms ____ required to be connected to an AFCI protected circuit.
(Multiple Choice)
4.9/5
(84)
The two most common types of smoke detectors are ____________________ and ____________________.
(Short Answer)
4.8/5
(76)
NFPA 72 requires that equipment be installed according to ____________________ instructions.
(Short Answer)
4.7/5
(80)
A wall-mounted smoke alarm shall not be mounted further than ____ in. from the corner where the ceiling meets the wall.
(Multiple Choice)
4.9/5
(90)
The National Fire Alarm Code (NFPA 72) requires that fire alarm equipment be ____.
(Multiple Choice)
4.9/5
(76)
A(n) ____ is a device suitable for connection to a circuit that has a sensor that responds to a physical stimulus such as heat or smoke.
(Multiple Choice)
4.9/5
(83)
The importance of installing smoke and fire alarms in homes is supported by results from exhaustive investigations of home fires indicating that ____.
(Multiple Choice)
5.0/5
(71)
In newly constructed homes, smoke detectors are required to have ____ for the primary source of power.
(Multiple Choice)
4.7/5
(78)
The photoelectric type of alarm is less effective for gasoline and alcohol fires, which do not produce heavy smoke.
(True/False)
4.9/5
(75)
A smoke alarm on a flat ceiling shall be mounted at least ____ in. away from the corner.
(Multiple Choice)
4.9/5
(73)
Article 760 of the National Electrical Code contains requirements for installing ____________________ for fire alarm systems.
(Short Answer)
4.8/5
(73)