Exam 16: Branch Circuits for the Garage and Outdoors

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

Type UF "underground feeder" cable ____ permitted to be used to supply service entrances.

Free
(Multiple Choice)
4.9/5
(78)
Correct Answer:
Verified

B

To provide shock protection, low-voltage wiring systems are required by Article 411 to be ____.

Free
(Multiple Choice)
4.8/5
(75)
Correct Answer:
Verified

C

The last sentence of 250.4(A)(5) states that "the earth shall not be considered as an effective ____________________."

Free
(Short Answer)
4.8/5
(87)
Correct Answer:
Verified

ground-fault current path
ground fault current path

The minimum depth for a 120-volt, 15-ampere, GFCI-protected circuit to an outdoor pole light run under a paved driveway is ____.

(Multiple Choice)
4.9/5
(68)

What type of cable is permitted to be used for direct burial applications?

(Multiple Choice)
4.9/5
(71)

Minimum cover requirements for direct-buried cables and raceways under a variety of conditions are given in Table ____________________.

(Short Answer)
4.9/5
(78)

Outdoor lighting fixtures and associated equipment ____ permitted to be supported by trees.

(Multiple Choice)
4.9/5
(77)

Direct-burial cable is normally required to have a minimum of 24 inches of earth cover. Explain the conditions under which the minimum depth can be reduced to 12 inches for residential occupancies.

(Essay)
4.7/5
(78)

When outdoor receptacles are installed where a cord will be plugged in permanently, such as for decorative lighting, the box cover ____ maintain weatherproof integrity when the cord is plugged in.

(Multiple Choice)
4.8/5
(81)

Explain why, in colder parts of the country, incandescent fixtures are more suitable than fluorescent for unheated spaces like garages.

(Essay)
4.8/5
(82)

Metallic conduit buried underground must be protected against ____.

(Multiple Choice)
4.9/5
(98)

Permanent overhead conductor spans are permitted to be supported by live or dead vegetation, such as trees.

(True/False)
5.0/5
(93)

Explain the rationale for installing supplemental overcurrent protection, such as a "box cover unit" with a switch and fuse combination, to protect an appliance or utilization equipment such as a garage door opener.

(Essay)
4.9/5
(74)

Conductors suitable for use in ____________________ locations will have the letter "W" in their type designation.

(Short Answer)
4.9/5
(77)

Explain why a post lamp cannot be grounded only with a local ground rod, but must have a separate grounding equipment conductor going back to the residential service.

(Essay)
4.8/5
(88)

The recommended approach to provide adequate lighting in a residential garage is to install one ____-watt lamp on the ceiling above each side of an automobile.

(Multiple Choice)
4.9/5
(75)

If you are experiencing too much lamp burnout in your garage door opener, the culprit is probably vibration.

(True/False)
4.9/5
(76)

Article ____________________ covers low-voltage lighting systems operating at 30 volts RMS or less.

(Short Answer)
4.8/5
(76)

Overhead conductors ____ permitted to be supported by trees.

(Multiple Choice)
4.8/5
(82)

According to NEC 210.52(G), at least ____ receptacle(s) must be installed in an attached residential garage.

(Multiple Choice)
4.9/5
(81)