Exam 37: Storage and Delivery of Medical Gases

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Which of the following is/are considered therapeutic gases? I.O2 II.O2-NO mixture III.O2-He mixture IV.N2O

(Multiple Choice)
4.9/5
(82)

What cylinder factor is used to compute the duration of flow for a 22 cu/ft O2 or air E cylinder?

(Multiple Choice)
4.8/5
(74)

Which of the following equipment could be powered by a small diaphragm or turbine air compressor? I.small-volume medication nebulizer II.all-purpose large-volume jet nebulizer III.intermittent positive-pressure breathing device

(Multiple Choice)
4.7/5
(80)

When used to control the flow of medical gases to a patient, how is a Bourdon gauge classified?

(Multiple Choice)
4.9/5
(81)

What cylinder factor is used to compute the duration of flow for a 244 cu/ft (H/K) O2 or air cylinder?

(Multiple Choice)
4.7/5
(80)

Where do respiratory therapists typically find DISS connections? I.at the outlets of pressure-reducing valves attached to cylinders II.at the nurse station III.at the station outlets of central piping systems IV.at the inlets of blenders, flowmeters, ventilators, and other pneumatic equipment

(Multiple Choice)
4.9/5
(79)

What is the fire-risk classification of N and CO2?

(Multiple Choice)
4.9/5
(69)

Cylinders of liquid gases are filled according to what specification?

(Multiple Choice)
4.9/5
(88)

If you had to power a ventilator from a large cylinder of compressed gas, which of the following devices would be required?

(Multiple Choice)
4.9/5
(78)

Components of a large medical air compressor include which of the following? I.drying system II.diaphragm or turbine III.reservoir tank IV.pressure-reducing valve

(Multiple Choice)
4.9/5
(89)

One cubic foot of any gas is equivalent to how many liters of gas?

(Multiple Choice)
4.9/5
(71)

Which of the following devices would you select if the goal was to accurately meter the flow through a jet nebulizer?

(Multiple Choice)
4.8/5
(73)

Structural requirements for the central piping systems that are used in hospitals to distribute gases are established by whom?

(Multiple Choice)
4.8/5
(88)

The gauge on an H cylinder of O2 reads 2000 psig. About how long would the contents of this cylinder last, until completely empty, at a flow of 6 L/min?

(Multiple Choice)
4.8/5
(70)

Which of the following components are common to a standard compressed gas cylinder manifold system? I.automatic switch-over control II.pressure-reducing valves III.primary and reserve bank IV.alarm system

(Multiple Choice)
5.0/5
(84)

Which of the following mechanisms do all compressed gas cylinders use to avoid excessively high buildup of cylinder pressure?

(Multiple Choice)
4.8/5
(76)

Which of the following is FALSE about a Bourdon gauge?

(Multiple Choice)
4.9/5
(77)

Which of the following statements about CO2 is FALSE?

(Multiple Choice)
4.7/5
(73)

Which of the following are advantages of a using a flow restrictor to control the delivery of medical gases to a patient? I.preset metered flow II.low cost and simplicity III.gravity independence IV.wide range of utility

(Multiple Choice)
4.9/5
(77)

According to the U.S. Department of Commerce, a gas cylinder that is color coded blue should contain which of the following?

(Multiple Choice)
4.7/5
(73)
Showing 61 - 80 of 80
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)