Exam 12: Blood Bank Technologies and Automation
Exam 1: Red Blood Cells and Platelet Preservation: Historical Perspectives and Current Trends44 Questions
Exam 2: Basic Genetics40 Questions
Exam 3: Fundamentals of Immunology69 Questions
Exam 4: Concepts in Molecular Biology45 Questions
Exam 5: The Antiglobulin Test46 Questions
Exam 6: The Abo Blood Group System69 Questions
Exam 7: The Rh Blood Group System50 Questions
Exam 8: Blood Group Terminology and Common Blood Groups185 Questions
Exam 9: Uncommon Blood Groups63 Questions
Exam 10: Detection and Identification of Antibodies78 Questions
Exam 11: Pre-Transfusion Testing35 Questions
Exam 12: Blood Bank Technologies and Automation23 Questions
Exam 13: Donor Selection50 Questions
Exam 14: Transfusion-Transmitted Diseases45 Questions
Exam 15: Component Preparation52 Questions
Exam 16: Transfusion Therapy100 Questions
Exam 17: Adverse Effects of Blood Transfusion88 Questions
Exam 18: Apheresis60 Questions
Exam 19: Cellular Therapy in the Transplant Setting64 Questions
Exam 20: Hemolytic Disease of the Fetus and Newborn55 Questions
Exam 21: Autoimmune Hemolytic Anemias66 Questions
Exam 22: Tissue Banking As Part of the Transfusion Service28 Questions
Exam 23: The Hla System51 Questions
Exam 24: Relationship Testing33 Questions
Exam 25: Quality Management61 Questions
Exam 26: Patient Blood Management27 Questions
Exam 27: Transfusion Safety and Federal Regulatory Requirements36 Questions
Exam 28: Laboratory Information Systems in the Blood Bank39 Questions
Exam 29: Medicolegal and Ethical Aspects of Providing Blood Collection and Transfusion Services32 Questions
Select questions type
Low ionic strength saline (LISS) is added to antibody screening methods for which of the following test systems?
Free
(Multiple Choice)
4.8/5
(86)
Correct Answer:
B
SPRCA testing requires the use of all of these specialized microplate equipment EXCEPT:
Free
(Multiple Choice)
4.9/5
(82)
Correct Answer:
C
Which of the following tests is not available for both the gel testing method and solid phase technology?
Free
(Multiple Choice)
4.8/5
(83)
Correct Answer:
C
Manufacturers Grifols and Ortho both produce automated blood bank equipment that uses
(Multiple Choice)
4.9/5
(78)
In a gel-based technology, the solid band at the top of the gel indicates a , whereas formation of a pellet at the bottom of the microtubes indicates .
(Multiple Choice)
4.9/5
(78)
Using the gel test system, the technologist used a 3% cell solution. What would be the probable outcome?
(Multiple Choice)
4.8/5
(85)
Upon centrifugation of an antibody screen procedure done by the gel system, the red blood cell agglutinates are dispersed throughout the gel column with a few agglutinates at the bottom of the microtubes. This reaction should be graded as a:
(Multiple Choice)
4.8/5
(78)
Using the affinity column technique, a serologic reaction that forms a fine red blood cell band at the top of the gel column and a red blood cell button at the bottom of the gel column is interpreted as:
(Multiple Choice)
4.8/5
(83)
A layer of red blood cells agglutinates at the top of the gel media, and a pellet of unagglutinated red blood cells forms at the bottom. These findings are comparable to which of the following reactions in the test tube?
(Multiple Choice)
4.7/5
(78)
Which of the following statements is the most accurate? A mixed-field in the gel system:
(Multiple Choice)
4.8/5
(93)
Which of the following substances may interfere with gel technology but not SPRCA technology?
(Multiple Choice)
4.7/5
(98)
When performing an antibody screen by gel technology, the following steps are eliminated:
(Multiple Choice)
4.7/5
(76)
The indicator cells used to detect antibodies in a solid phase technology are:
(Multiple Choice)
4.7/5
(86)
If you had a lipemic and icteric sample that needed to have an antibody screen done, which of the following would obtain the best results?
(Multiple Choice)
4.8/5
(79)
An anti-M detected by using gel AHG antibody screening cards is considered clinically insignificant.
(True/False)
4.9/5
(92)
The gel system has all of the following advantages over the traditional tube procedure except:
(Multiple Choice)
4.9/5
(80)
In performing an antibody screen by the solid phase technique, a monolayer of red blood cells is formed at the top of the microplate wells following the addition of indicator cells. This result should be interpreted as:
(Multiple Choice)
4.9/5
(77)
Which of the following factors are likely to cause false-positive results while using gel technology?
(Multiple Choice)
4.9/5
(82)
Showing 1 - 20 of 23
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)