Exam 46: Room Air Conditioners
Exam 1: Heat and Pressure45 Questions
Exam 2: Matter and Energy32 Questions
Exam 3: Refrigeration and Refrigerants38 Questions
Exam 4: General Safety Practices31 Questions
Exam 5: Tools and Equipment30 Questions
Exam 6: Fasteners32 Questions
Exam 7: Tubing and Piping45 Questions
Exam 8: Leak Detection, System Evacuation and System Clean-Up33 Questions
Exam 9: Refrigerant and Oil Chemistry and Managementrecovery, Recycling, Reclaiming, and Retrofitting39 Questions
Exam 10: System Charging27 Questions
Exam 11: Calibrating Instruments34 Questions
Exam 12: Basic Electricity and Magnetism46 Questions
Exam 13: Introduction to Automatic Controls30 Questions
Exam 14: Automatic Control Components and Applications34 Questions
Exam 15: Troubleshooting Basic Controls33 Questions
Exam 16: Advanced Automatic Controlsdirect Digital Controls Ddc and Pneumatics35 Questions
Exam 17: Types of Electric Motors36 Questions
Exam 18: Application of Motors33 Questions
Exam 19: Motor Controls31 Questions
Exam 20: Troubleshooting Electric Motors30 Questions
Exam 21: Evaporators and the Refrigeration System37 Questions
Exam 22: Condensers35 Questions
Exam 23: Compressors35 Questions
Exam 24: Expansion Devices29 Questions
Exam 25: Special Refrigeration System Components35 Questions
Exam 26: Application of Refrigeration Systems34 Questions
Exam 27: Commercial Ice Machines35 Questions
Exam 28: Special Refrigeration Applications27 Questions
Exam 29: Troubleshooting and Typical Operating Conditions for Commercial Refrigeration34 Questions
Exam 30: Electric Heat29 Questions
Exam 31: Gas Heat27 Questions
Exam 32: Oil Heat35 Questions
Exam 33: Hydronic Heat35 Questions
Exam 34: Indoor Air Quality35 Questions
Exam 35: Comfort and Psychrometrics35 Questions
Exam 36: Refrigeration Applied to Air Conditioning31 Questions
Exam 37: Air Distribution and Balance35 Questions
Exam 38: Installation32 Questions
Exam 39: Residential Energy Auditing35 Questions
Exam 40: Typical Operating Conditions25 Questions
Exam 41: Troubleshooting28 Questions
Exam 42: Heat Gain and Heat Loss in Buildings35 Questions
Exam 43: Air Source Heat Pumps35 Questions
Exam 44: Geothermal Heat Pumps31 Questions
Exam 45: Domestic Refrigerators and Freezers35 Questions
Exam 46: Room Air Conditioners34 Questions
Exam 47: High-Pressure, Low-Pressure, and Absorption Chilled-Water Systems35 Questions
Exam 48: Cooling Towers and Pumps30 Questions
Exam 49: Operation, Maintenance, and Troubleshooting of Chilled-Water Air Conditioning Systems28 Questions
Exam 50: Commercial Rooftop, Packaged, Variable Refrigerant Flow, and Variable Air Volume Systems35 Questions
Select questions type
The metering device in a modern room air conditioner is a(n) ____________________.
Free
(Short Answer)
5.0/5
(77)
Correct Answer:
capillary tube
Why may the window unit installation be considered temporary and the through-the-wall unit considered permanent?
Free
(Essay)
4.9/5
(82)
Correct Answer:
The window air conditioner may be removed and the window restored to its original use. The wall installation is permanent because a hole is cut in the wall and must be patched if the unit is removed.
Cooling-only window air conditioners range in size from about 4,000 Btu/h to 24,000 Btu/h.
Free
(True/False)
4.9/5
(76)
Correct Answer:
True
Heat exchange between the capillary tube and the suction line is typically found on window air conditioners.
(True/False)
4.8/5
(69)
To ensure correct direction of refrigerant flow in heat-pump-style room air conditioners, ____ are included in the unit.
(Multiple Choice)
4.9/5
(73)
Electrical service for a room unit may also involve the thermostat and the power cord.
(True/False)
4.9/5
(75)
In a heat-pump-style room air conditioner in the heating cycle, the indoor coil acts as the ____________________.
(Short Answer)
4.9/5
(88)
When servicing an R-410A window air conditioner, adjust the airflow across the condenser until the head pressure reaches ____.
(Multiple Choice)
5.0/5
(65)
In a heat-pump room air conditioner in the cooling cycle, the indoor coil acts as the ____________________.
(Short Answer)
4.8/5
(81)
If a window air conditioner is installed with an inward pitch, the condensate could leak into the room.
(True/False)
4.9/5
(88)
A heat-pump-style room air conditioner has all the major components of a cooling-only unit with the addition of a ____.
(Multiple Choice)
4.8/5
(65)
Cooling-only room air conditioners are marketed in ____ Btu/h capacities.
(Multiple Choice)
4.7/5
(85)
Central air conditioning systems operate with a design evaporator saturation temperature of about ____________________ºF.
(Short Answer)
4.7/5
(68)
Some cooling-only window air conditioners are equipped with energy-saver switches. What is their purpose?
(Essay)
4.8/5
(79)
What are the two advantages of draining the condensed moisture to the slinger system on the condenser?
(Essay)
4.9/5
(71)
Why do room air conditioners ice up easier than central air-conditioning systems?
(Essay)
4.8/5
(89)
The evaporator typically operates _____ the dew point temperature of the room air.
(Multiple Choice)
4.8/5
(63)
How many air moving motors do cooling-only room air conditioners usually have?
(Short Answer)
5.0/5
(82)
The condensate off the evaporator coil in a room air conditioner is generally disposed of by ____.
(Multiple Choice)
4.8/5
(74)
Showing 1 - 20 of 34
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)