The metering device in a modern room air conditioner is a(n) ____________________.

Free
(Short Answer)
5.0/5
(77)
Correct Answer:
Verified

capillary tube

Why may the window unit installation be considered temporary and the through-the-wall unit considered permanent?

Free
(Essay)
4.9/5
(82)
Correct Answer:
Verified

The window air conditioner may be removed and the window restored to its original use. The wall installation is permanent because a hole is cut in the wall and must be patched if the unit is removed.

Cooling-only window air conditioners range in size from about 4,000 Btu/h to 24,000 Btu/h.

Free
(True/False)
4.9/5
(76)
Correct Answer:
Verified

True

Heat exchange between the capillary tube and the suction line is typically found on window air conditioners.

(True/False)
4.8/5
(69)

To ensure correct direction of refrigerant flow in heat-pump-style room air conditioners, ____ are included in the unit.

(Multiple Choice)
4.9/5
(73)

Electrical service for a room unit may also involve the thermostat and the power cord.

(True/False)
4.9/5
(75)

In a heat-pump-style room air conditioner in the heating cycle, the indoor coil acts as the ____________________.

(Short Answer)
4.9/5
(88)

When servicing an R-410A window air conditioner, adjust the airflow across the condenser until the head pressure reaches ____.

(Multiple Choice)
5.0/5
(65)

All 230-V power supplies use the same style plug.

(True/False)
4.8/5
(79)

In a heat-pump room air conditioner in the cooling cycle, the indoor coil acts as the ____________________.

(Short Answer)
4.8/5
(81)

If a window air conditioner is installed with an inward pitch, the condensate could leak into the room.

(True/False)
4.9/5
(88)

A heat-pump-style room air conditioner has all the major components of a cooling-only unit with the addition of a ____.

(Multiple Choice)
4.8/5
(65)

Cooling-only room air conditioners are marketed in ____ Btu/h capacities.

(Multiple Choice)
4.7/5
(85)

Central air conditioning systems operate with a design evaporator saturation temperature of about ____________________ºF.

(Short Answer)
4.7/5
(68)

Some cooling-only window air conditioners are equipped with energy-saver switches. What is their purpose?

(Essay)
4.8/5
(79)

What are the two advantages of draining the condensed moisture to the slinger system on the condenser?

(Essay)
4.9/5
(71)

Why do room air conditioners ice up easier than central air-conditioning systems?

(Essay)
4.8/5
(89)

The evaporator typically operates _____ the dew point temperature of the room air.

(Multiple Choice)
4.8/5
(63)

How many air moving motors do cooling-only room air conditioners usually have?

(Short Answer)
5.0/5
(82)

The condensate off the evaporator coil in a room air conditioner is generally disposed of by ____.

(Multiple Choice)
4.8/5
(74)