Exam 43: Air Source Heat Pumps

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

When a compressor is changed, the four-way valve also must be changed.

Free
(True/False)
4.8/5
(88)
Correct Answer:
Verified

False

The smaller line in an air-to-air split-system heat pump is known as the ____ line.

Free
(Multiple Choice)
4.8/5
(66)
Correct Answer:
Verified

D

An air-to-air heat pump ____ heat from the outside air and deposits it in the conditioned space.

Free
(Multiple Choice)
4.8/5
(74)
Correct Answer:
Verified

B

When oil or gas auxiliary heat is used with a heat pump, the heat pump indoor coil must be located  ____________________ of the oil or gas heat exchanger.

(Short Answer)
4.9/5
(73)

What prevents cold air from being circulated to the heated space during the defrost cycle?

(Multiple Choice)
4.9/5
(87)

A(n) ____________________ thermostatic expansion valve has a check valve built into the body of the TXV.

(Short Answer)
4.9/5
(69)

The larger line in an air-to-air split-system heat pump is known as the ____ line.

(Multiple Choice)
4.9/5
(84)

What is it meant by the terminology "time or temperature terminated" defrost cycle?

(Essay)
4.8/5
(91)

The component used to switch the heat pump unit between the heating and cooling modes of operation is the ____.

(Multiple Choice)
4.8/5
(69)

Most heat pump systems are designed to operate in the heating mode when the solenoid is not energized. This is referred to as "____________________ in the heating mode".

(Short Answer)
4.8/5
(69)

The lowest outside air temperature at which the heat pump system can satisfy the heating needs of the structure without requiring auxiliary heat is called the ____________________.

(Short Answer)
4.9/5
(86)

The ____________________ is a four-port valve that has a slide mechanism in it.

(Short Answer)
4.9/5
(71)

When a heat pump is added to an electric furnace, the indoor coil must be located after the ____________________ strips.

(Short Answer)
4.7/5
(75)

The coil of the air-to-air heat pump system that is the indoor unit is known as the ____________________ in the heating mode.

(Short Answer)
4.8/5
(88)

Some heat pump systems when not capable of meeting the heating needs of the structure are equipped with second-stage heat, called ____________________.

(Short Answer)
4.9/5
(93)

It is common for the outdoor unit to ice-up when the heat pump is operated in the cooling mode.

(True/False)
4.9/5
(88)

The coil of the air-to-air heat pump system that is the indoor unit is known as the ____________________ in the cooling mode.

(Short Answer)
4.9/5
(75)

The term ____________________ indicates the source of heat while the system is operating in the heating mode and the medium that is ultimately being treated.

(Short Answer)
4.7/5
(92)

In the emergency heat mode, the auxiliary heat source becomes the primary heat source because of heat pump failure.

(True/False)
4.9/5
(76)

In heat pump systems the sensing bulb is typically exposed to high temperatures and could rupture the valve diaphragm. For this reason, a(n) ____________________ TVX is usually used.

(Short Answer)
4.8/5
(70)
Showing 1 - 20 of 35