When charging a refrigeration system with a near-azeotropic mixture, what must be done to prevent liquid from entering the system?

Free
(Multiple Choice)
4.9/5
(73)
Correct Answer:
Verified

C

A manufacturer's charging chart may be used when available to determine the correct charge for a system.

Free
(True/False)
4.9/5
(89)
Correct Answer:
Verified

True

One good feature of an electronic charging scale is that it counts upward as refrigerant is removed, to tell the technician how much refrigerant was used.

Free
(True/False)
5.0/5
(78)
Correct Answer:
Verified

True

When adding refrigerant in liquid form into the high-side of the system, the system motor/compressor assembly is running.

(True/False)
4.7/5
(76)

When charging a system with vapor refrigerant from a refrigerant cylinder, the cylinder will become ____.

(Multiple Choice)
4.8/5
(87)

Refrigerant in vapor form is normally put into the system through the ____.

(Multiple Choice)
4.8/5
(70)

The factory charge in a split system, using R-22, shows 6 lb. 8 oz. in the outdoor condensing unit and 2 oz. in the evaporator. The 3/8" liquid line contains 0.48 oz. per foot and the 7/8" suction line contains 0.10 oz. per foot. The refrigerant lines are 30' long. What is the correct refrigerant charge for this system?

(Multiple Choice)
5.0/5
(75)

Using a restrictor, liquid refrigerant can be charged into the low-side of the system with the system operating.

(True/False)
5.0/5
(92)

If 30 oz. of refrigerant are to be added to a refrigeration system and the supply cylinder weighs 26 lb. 4 oz. before any is added, what will the supply cylinder weigh after the system has been charged?

(Multiple Choice)
4.8/5
(78)

If a critically charged refrigeration system is over charged, which of the following is a likely result?

(Multiple Choice)
4.7/5
(83)

The ____________________ is used to help technicians perform a number of tasks including taking pressure readings on the high side of the system and trapping all of the system refrigerant in the receiver to perform system service.

(Short Answer)
4.8/5
(95)

When charging liquid refrigerant from a single valve supply cylinder, the cylinder is placed ____.

(Multiple Choice)
4.9/5
(80)

Refrigerant in liquid form is normally put into the system through the ____.

(Multiple Choice)
4.9/5
(81)

The charging device that holds refrigerant, has a visible column of liquid, and can be used to "visually" see the amount of refrigerant used is called the ____________________.

(Short Answer)
4.9/5
(73)

When the warm refrigerant cylinder is connected to an operating system, the pressure in the cylinder will be ____________________ than the suction pressure of the system.

(Short Answer)
4.7/5
(83)

When the system pressures are lower than the pressure in the refrigerant tank, such as when the system has just been evacuated or if the system is out of refrigerant, refrigerant can be added to both the high and low pressure sides of the system.

(True/False)
4.8/5
(81)

Charging a refrigeration system refers to ____.

(Multiple Choice)
4.8/5
(77)

Fractionation occurs when ____.

(Multiple Choice)
4.9/5
(74)

The quickest method to charge a system is to charge only vapor.

(True/False)
4.7/5
(72)

Refrigerant in vapor form is added to an operating system through the ____________________ side of the system.

(Short Answer)
4.9/5
(86)