Exam 17: Types of Electric Motors
Exam 1: Heat and Pressure45 Questions
Exam 2: Matter and Energy32 Questions
Exam 3: Refrigeration and Refrigerants38 Questions
Exam 4: General Safety Practices31 Questions
Exam 5: Tools and Equipment30 Questions
Exam 6: Fasteners32 Questions
Exam 7: Tubing and Piping45 Questions
Exam 8: Leak Detection, System Evacuation and System Clean-Up33 Questions
Exam 9: Refrigerant and Oil Chemistry and Managementrecovery, Recycling, Reclaiming, and Retrofitting39 Questions
Exam 10: System Charging27 Questions
Exam 11: Calibrating Instruments34 Questions
Exam 12: Basic Electricity and Magnetism46 Questions
Exam 13: Introduction to Automatic Controls30 Questions
Exam 14: Automatic Control Components and Applications34 Questions
Exam 15: Troubleshooting Basic Controls33 Questions
Exam 16: Advanced Automatic Controlsdirect Digital Controls Ddc and Pneumatics35 Questions
Exam 17: Types of Electric Motors36 Questions
Exam 18: Application of Motors33 Questions
Exam 19: Motor Controls31 Questions
Exam 20: Troubleshooting Electric Motors30 Questions
Exam 21: Evaporators and the Refrigeration System37 Questions
Exam 22: Condensers35 Questions
Exam 23: Compressors35 Questions
Exam 24: Expansion Devices29 Questions
Exam 25: Special Refrigeration System Components35 Questions
Exam 26: Application of Refrigeration Systems34 Questions
Exam 27: Commercial Ice Machines35 Questions
Exam 28: Special Refrigeration Applications27 Questions
Exam 29: Troubleshooting and Typical Operating Conditions for Commercial Refrigeration34 Questions
Exam 30: Electric Heat29 Questions
Exam 31: Gas Heat27 Questions
Exam 32: Oil Heat35 Questions
Exam 33: Hydronic Heat35 Questions
Exam 34: Indoor Air Quality35 Questions
Exam 35: Comfort and Psychrometrics35 Questions
Exam 36: Refrigeration Applied to Air Conditioning31 Questions
Exam 37: Air Distribution and Balance35 Questions
Exam 38: Installation32 Questions
Exam 39: Residential Energy Auditing35 Questions
Exam 40: Typical Operating Conditions25 Questions
Exam 41: Troubleshooting28 Questions
Exam 42: Heat Gain and Heat Loss in Buildings35 Questions
Exam 43: Air Source Heat Pumps35 Questions
Exam 44: Geothermal Heat Pumps31 Questions
Exam 45: Domestic Refrigerators and Freezers35 Questions
Exam 46: Room Air Conditioners34 Questions
Exam 47: High-Pressure, Low-Pressure, and Absorption Chilled-Water Systems35 Questions
Exam 48: Cooling Towers and Pumps30 Questions
Exam 49: Operation, Maintenance, and Troubleshooting of Chilled-Water Air Conditioning Systems28 Questions
Exam 50: Commercial Rooftop, Packaged, Variable Refrigerant Flow, and Variable Air Volume Systems35 Questions
Select questions type
The resistances of the windings in a three phase motor are all equal.
Free
(True/False)
5.0/5
(73)
Correct Answer:
True
The difference between synchronous speed and full load speed is called ____________________.
Free
(Short Answer)
4.8/5
(81)
Correct Answer:
slip
Once the start winding and the start capacitor have been removed for the circuit, the motor will continue to operate with only the run winding energized.
Free
(True/False)
4.8/5
(78)
Correct Answer:
True
The centrifugal switch mounted on the shaft of a split-phase motor has a normally closed contact.
(True/False)
4.9/5
(80)
A motor that has copper bars in the rotor is classified as a(n) ____________________ type.
(Short Answer)
4.8/5
(78)
When a Capacitor Start Induction Run (CSIR) motor is running and up to speed, what is the total capacitance acting on the motor? (Assume the run capacitor is 5 microfarads and the start capacitor is 20 microfarads, if present.)
(Multiple Choice)
4.9/5
(90)
The windings of the relay coil in a current relay has very low resistance. Why?
(Essay)
4.8/5
(80)
The heavier the load on an operating motor, the greater the amount of slip.
(True/False)
4.9/5
(79)
When a general duty split-phase motor reaches approximately 75% of its operating speed, the start winding is de-energized by a ____.
(Multiple Choice)
4.9/5
(61)
A split-phase motor that has a current relay and a start capacitor is called a(n) ____ motor.
(Multiple Choice)
4.9/5
(94)
A current magnetic relay opens and closes its contacts based on the ____.
(Multiple Choice)
4.9/5
(79)
The positive temperature coefficient resistor start device is a type of ____.
(Multiple Choice)
4.8/5
(79)
When not air cooled, the heat generated by the motor in a hermetic motor-compressor assembly is removed by what?
(Short Answer)
4.8/5
(91)
The rotating portion of an electric motor is called the ____________________.
(Short Answer)
4.8/5
(83)
Capacitors wired in series with the starting winding provide a(n) ____.
(Multiple Choice)
5.0/5
(91)
The microfarad rating of the run capacitor is much lower than that of the start capacitor for any given motor application.
(True/False)
4.9/5
(69)
A Capacitor Start Capacitor Run (CSCR) motor that is wired with a potential relay will have the start winding energized when the relay's contacts open.
(True/False)
4.8/5
(85)
The coil of a potential relay has ____________________ resistance.
(Short Answer)
5.0/5
(88)
Showing 1 - 20 of 36
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)