Exam 44: Geothermal Heat Pumps
Exam 1: Heat and Pressure45 Questions
Exam 2: Matter and Energy32 Questions
Exam 3: Refrigeration and Refrigerants38 Questions
Exam 4: General Safety Practices31 Questions
Exam 5: Tools and Equipment30 Questions
Exam 6: Fasteners32 Questions
Exam 7: Tubing and Piping45 Questions
Exam 8: Leak Detection, System Evacuation and System Clean-Up33 Questions
Exam 9: Refrigerant and Oil Chemistry and Managementrecovery, Recycling, Reclaiming, and Retrofitting39 Questions
Exam 10: System Charging27 Questions
Exam 11: Calibrating Instruments34 Questions
Exam 12: Basic Electricity and Magnetism46 Questions
Exam 13: Introduction to Automatic Controls30 Questions
Exam 14: Automatic Control Components and Applications34 Questions
Exam 15: Troubleshooting Basic Controls33 Questions
Exam 16: Advanced Automatic Controlsdirect Digital Controls Ddc and Pneumatics35 Questions
Exam 17: Types of Electric Motors36 Questions
Exam 18: Application of Motors33 Questions
Exam 19: Motor Controls31 Questions
Exam 20: Troubleshooting Electric Motors30 Questions
Exam 21: Evaporators and the Refrigeration System37 Questions
Exam 22: Condensers35 Questions
Exam 23: Compressors35 Questions
Exam 24: Expansion Devices29 Questions
Exam 25: Special Refrigeration System Components35 Questions
Exam 26: Application of Refrigeration Systems34 Questions
Exam 27: Commercial Ice Machines35 Questions
Exam 28: Special Refrigeration Applications27 Questions
Exam 29: Troubleshooting and Typical Operating Conditions for Commercial Refrigeration34 Questions
Exam 30: Electric Heat29 Questions
Exam 31: Gas Heat27 Questions
Exam 32: Oil Heat35 Questions
Exam 33: Hydronic Heat35 Questions
Exam 34: Indoor Air Quality35 Questions
Exam 35: Comfort and Psychrometrics35 Questions
Exam 36: Refrigeration Applied to Air Conditioning31 Questions
Exam 37: Air Distribution and Balance35 Questions
Exam 38: Installation32 Questions
Exam 39: Residential Energy Auditing35 Questions
Exam 40: Typical Operating Conditions25 Questions
Exam 41: Troubleshooting28 Questions
Exam 42: Heat Gain and Heat Loss in Buildings35 Questions
Exam 43: Air Source Heat Pumps35 Questions
Exam 44: Geothermal Heat Pumps31 Questions
Exam 45: Domestic Refrigerators and Freezers35 Questions
Exam 46: Room Air Conditioners34 Questions
Exam 47: High-Pressure, Low-Pressure, and Absorption Chilled-Water Systems35 Questions
Exam 48: Cooling Towers and Pumps30 Questions
Exam 49: Operation, Maintenance, and Troubleshooting of Chilled-Water Air Conditioning Systems28 Questions
Exam 50: Commercial Rooftop, Packaged, Variable Refrigerant Flow, and Variable Air Volume Systems35 Questions
Select questions type
The ______________________ is nothing more than a large tank that both receives water from the condenser as well as supplying water to the condenser.
Free
(Short Answer)
4.7/5
(87)
Correct Answer:
buffer tank
What are return wells used for?
Free
(Essay)
4.8/5
(93)
Correct Answer:
Return wells are used to discharge the water back into the ground after it has experienced the heat pump's heat exchanger.
In a geothermal heat pump system, there is a refrigerant loop and a water (water and antifreeze) loop.
Free
(True/False)
4.8/5
(81)
Correct Answer:
True
In a closed-loop system, the same fluid (water or water and antifreeze) will absorb heat from the ground in the winter and reject the heat to the ground in the summer.
(True/False)
4.8/5
(73)
What is the temperature differential between water in and water out of a heat exchanger that has transferred 50,000 Btu/h? The flow rate is 10 gallons per minute.
(Multiple Choice)
4.9/5
(83)
A(n) ____________________ blower is used to move the air through the air distribution system.
(Short Answer)
4.8/5
(67)
A dry well is most commonly used as part of a(n) ____________________ system.
(Short Answer)
4.8/5
(82)
In order to prevent water contamination, wells used for geothermal heat pump systems are grouted.
(True/False)
4.9/5
(82)
The hot gas line from the heat pump's compressor can be used to ____.
(Multiple Choice)
4.7/5
(95)
Before deciding to purchase or install an open-loop system, the ____________________ must be evaluated first.
(Short Answer)
4.7/5
(89)
Scale results in a low head pressure in the cooling mode and high suction pressure in the heating mode.
(True/False)
4.9/5
(86)
A "dedicated" geothermal well is part of a(n) ____________________ system.
(Short Answer)
5.0/5
(80)
Temperature, quantity, and cleanliness are three important factors that should be addressed when referring to water quality.
(True/False)
4.9/5
(68)
Geothermal heat pumps use the ____________________ water as a heat source or a heat sink.
(Short Answer)
4.9/5
(88)
An advantage of a "parallel flow" configuration of ground loops is ____.
(Multiple Choice)
4.9/5
(90)
The inner tube of heat exchangers of water-source heat pumps have extended surfaces called ____________________, which increase the surface area for better heat transfer.
(Short Answer)
4.8/5
(74)
The ground loop configuration that is used when there is a shortage of land is the ____________________.
(Short Answer)
5.0/5
(91)
Showing 1 - 20 of 31
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)