Exam 22: Condensers

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Low suction pressures, iced coils, short cycling, and inefficient cooling, can also result from low head pressures .

Free
(True/False)
4.8/5
(69)
Correct Answer:
Verified

True

The shell-and-tube condenser is cleaned ____.

Free
(Multiple Choice)
4.8/5
(94)
Correct Answer:
Verified

A

Describe the construction of the tube-within-a-tube condensers .

Free
(Essay)
4.8/5
(80)
Correct Answer:
Verified

The tube-within-a-tube is manufactured by slipping one pipe inside another and sealing the ends in such a manner that the outer tube becomes one container and the inner tube becomes another container. The two pipes are then formed into a coil to save space .

If the spring pressure of a water regulating valve is increased, the system head pressure will also increase.

(True/False)
4.8/5
(90)

In a recirculating water system condenser, the leaving water temperature is normally ____________________°F lower than the condensing temperature of the refrigerant .

(Short Answer)
4.7/5
(81)

In a water-cooled condenser with dirty condenser tubes, the temperature difference between the refrigerant and the leaving water will be ____ when the tubes are clean.

(Multiple Choice)
4.9/5
(76)

In a water-cooled condenser, a regulating valve is used to control the ____.

(Multiple Choice)
4.8/5
(74)

The refrigerant in a condenser in a refrigeration system ____.

(Multiple Choice)
4.9/5
(83)

When the evaporative condenser is used in cold climates, freeze protection must be provided in winter .

(True/False)
5.0/5
(79)

If an R-12 refrigeration system has its air-cooled condensing unit on a roof with an ambient air temperature of 100°F and the condenser outlet temperature (refrigerant) is 115°F, with how much subcooling is the condenser operating ?

(Multiple Choice)
5.0/5
(74)

The typical design temperature for the water entering a recirculating water system condenser is 85°F, and most systems have a ____ rise across the condenser.

(Multiple Choice)
4.7/5
(71)

In order for a flooded condenser type head pressure control system to operate, a device called a(n) ____________________ holds the extra refrigerant in warmer weather when the condenser doesn't need to be flooded .

(Short Answer)
4.9/5
(79)

A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible ?

(Multiple Choice)
4.8/5
(79)

The heat in the vicinity of the ____________________ gas has a tendency to cause any minerals in the water to deposit onto the tube surface.

(Short Answer)
4.8/5
(98)

Which of the following can be used to maintain the head pressure of a system with an air-cooled condenser?

(Multiple Choice)
4.8/5
(88)

The water circuit in shell-and-coil and tube-within-a-tube coil condensers must be cleaned ____.

(Multiple Choice)
4.7/5
(73)

High head pressures from low ambients can cause insufficient refrigerant flow rates through metering devices, which in turn can starve evaporators .

(True/False)
4.9/5
(81)

What can be used to maintain the head pressure of a system with a water-cooled condenser?

(Multiple Choice)
4.8/5
(78)

A water regulating valve helps to maintain a system's head pressure by modulating the flow of refrigerant through the condenser.

(True/False)
4.9/5
(87)

Hard starting may also occur in a low ambient condition, causing low head pressures .

(True/False)
4.8/5
(92)
Showing 1 - 20 of 35