Exam 33: Hydronic Heat

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

The pressure relief valve ____.

Free
(Multiple Choice)
4.8/5
(81)
Correct Answer:
Verified

B

The series loop system is the hydronic system that is found most often, primarily because of the  ____.

Free
(Multiple Choice)
4.9/5
(82)
Correct Answer:
Verified

D

Hydronic heating systems are systems in which water or ____________________ carries the heat through pipes to the areas to be heated .

Free
(Short Answer)
4.9/5
(78)
Correct Answer:
Verified

steam

The reason for using zone valves on a hydronic heating system is to ____.

(Multiple Choice)
4.9/5
(69)

The high-limit control, like the ____________________, is a device that opens and closes its contacts in response to boiler water temperature .

(Short Answer)
4.9/5
(86)

Most residences with modern hydronic heating systems use ____________________ baseboard heat transfer for terminal heating units.

(Short Answer)
4.9/5
(81)

A series loop hydronic system is not desirable for use in a large residence because ____.

(Multiple Choice)
4.7/5
(68)

Pumps generally have a cast-iron body with the impeller and other moving parts made of ____________________ or nonferrous metals .

(Short Answer)
4.7/5
(85)

A column of water 1 ft high exerts a pressure of ____.

(Multiple Choice)
4.7/5
(76)

Air in a hydronic system can cause ____.

(Multiple Choice)
4.9/5
(76)

The more common type of expansion tank is the ____ expansion tank.

(Multiple Choice)
4.9/5
(80)

The more sections a boiler has, the higher its capacity will be.

(True/False)
4.8/5
(89)

It is important to note that the air separator does not remove air from the system .

(True/False)
4.9/5
(91)

An automatic air vent controls the airflow out of the system by means of a(n) ____________________, which rises and falls with the amount of air in the system.

(Short Answer)
4.8/5
(89)

A pressure relief valve is set at 30 psig. The valve is constantly opening and flooding the floor. What is causing the relief valve to constantly open?

(Multiple Choice)
4.8/5
(82)

The low-water ____________________ valve is responsible for deenergizing the hydronic system in the event the level of water in the system drops below the desired point .

(Short Answer)
4.9/5
(86)

Expansion tanks must always be bled from the top until all of the air is removed from it.

(True/False)
4.8/5
(82)

A tankless domestic water system provides hot water from a coil in the boiler.

(True/False)
4.8/5
(82)

Explain how a centrifugal circulating pump creates flow in the hydronic system .

(Essay)
4.9/5
(74)

In hot water hydronic systems, water is heated and circulated through pipes to a heat transfer component called a(n) ____________________ unit .

(Short Answer)
4.8/5
(79)