Exam 12: Introduction to Ventilators
Exam 1: Basic Physics for the Respiratory Therapist107 Questions
Exam 2: Principles of Infection Control95 Questions
Exam 3: Manufacture, Storage, and Transport of Medical Gases101 Questions
Exam 4: Administering Medical Gases: Regulators, Flowmeters, and97 Questions
Exam 5: Airway Management Devices and Advanced Cardiac Life Support70 Questions
Exam 6: Humidity and Aerosol Therapy88 Questions
Exam 7: Lung Expansion Therapy Devices57 Questions
Exam 8: Assessment of Pulmonary Function120 Questions
Exam 9: Assessment of Cardiovascular Function77 Questions
Exam 10: Blood Gas Monitoring96 Questions
Exam 11: Sleep Diagnostics37 Questions
Exam 12: Introduction to Ventilators107 Questions
Exam 13: Mechanical Ventilators: General-Use Devices45 Questions
Exam 14: Infant and Pediatric Devices96 Questions
Exam 15: Transport, Home Care, and Noninvasive Ventilatory Devices52 Questions
Select questions type
The figure shows the pressure-time scalar for a pressure-support breath.To alleviate the problem depicted in this figure,the respiratory therapist should do which of the following?

(Multiple Choice)
4.9/5
(75)
The mandatory breath begins as a pressure-controlled breath,but it switches to volume control during inspiration because a preset volume is not achieved. This describes which of the following control types?
(Multiple Choice)
4.8/5
(84)
The added clinical benefit of secretion removal is facilitated with which high-frequency mode of ventilation?
(Multiple Choice)
4.8/5
(78)
The description "a mode where each breath is pressure limited and the pressure-limit level is adjusted automatically between breaths by using ventilatory mechanics to minimize the patient's work of breathing" pertains to which ventilator control type?
(Multiple Choice)
4.8/5
(68)
A patient is receiving continuous positive airway pressure from a freestanding,continuous-flow system.The respiratory therapist notices the pressure-release valve venting on each patient exhalation.What action should the respiratory therapist take?
(Multiple Choice)
4.8/5
(81)
A closed-loop ventilator system can be described as which of the following?
1)Feedback
2)Hierarchical
3)Unintelligent
4)Servo-controlled
(Multiple Choice)
4.8/5
(78)
The gas that enters the ventilator from high-pressure sources goes directly to the patient.This is a description of a _____ system.
(Multiple Choice)
4.9/5
(82)
During pressure-targeted ventilation with volume guaranteed for every breath,the set volume is not met.Which of the following phase variables would cycle that breath?
(Multiple Choice)
4.8/5
(81)
Which two of the following patient triggers are most common?
1)Flow
2)Neural
3)Volume
4)Pressure
(Multiple Choice)
4.9/5
(85)
Pressure-support ventilation is classified as:
1)Flow cycled
2)Time triggered
3)Volume targeted
4)Pressure targeted
5)Patient triggered
(Multiple Choice)
4.9/5
(80)
What is the static lung compliance when the returned tidal volume is 500 mL,the baseline pressure is zero,and the plateau pressure reading is 25 cm H₂O?
(Multiple Choice)
4.7/5
(77)
What procedure is used to estimate the amount of air trapped in the patient's lungs and in the patient circuit?
(Multiple Choice)
4.9/5
(88)
The flow,volume,and pressure waveforms characteristic of a pressure-limited,time-cycled breath are represented in which column of the figure?

(Multiple Choice)
4.9/5
(74)
Which of the following control modes of ventilation consists of ventilator output automatically following a varying input (e.g.,volume or flow generated by the patient)?
(Multiple Choice)
4.8/5
(78)
If the base flow is 10 L/min and the flow-trigger setting is 4 L/min,the flow during the expiratory phase is _____ L/min.
(Multiple Choice)
4.8/5
(70)
With a baseline pressure setting of 6 cm H₂O and a sensitivity setting of -1.5 cm H₂O,inspiration will begin at _____ cm H₂O.
(Multiple Choice)
4.9/5
(84)
What variable begins the inspiratory phase of a ventilator?
(Multiple Choice)
4.8/5
(73)
The pressure maintained at the airway during exhalation is known as which of the following?
(Multiple Choice)
4.9/5
(80)
A patient receiving continuous positive airway pressure of 7.5 cm H₂O via a mask and freestanding system appears to be in distress.The patient is using accessory muscles and is diaphoretic. The manometer is fluctuating between -5 cm H₂O on inspiration and 7.5 cm H₂O on expiration.The most apparent cause of the patient's distress is which of the following?
(Multiple Choice)
4.9/5
(84)
On a mechanical ventilator,pressure triggering is usually set within which of the following ranges?
(Multiple Choice)
4.9/5
(82)