Exam 14: Infant and Pediatric Devices
Exam 1: Basic Physics for the Respiratory Therapist107 Questions
Exam 2: Principles of Infection Control95 Questions
Exam 3: Manufacture, Storage, and Transport of Medical Gases101 Questions
Exam 4: Administering Medical Gases: Regulators, Flowmeters, and97 Questions
Exam 5: Airway Management Devices and Advanced Cardiac Life Support70 Questions
Exam 6: Humidity and Aerosol Therapy88 Questions
Exam 7: Lung Expansion Therapy Devices57 Questions
Exam 8: Assessment of Pulmonary Function120 Questions
Exam 9: Assessment of Cardiovascular Function77 Questions
Exam 10: Blood Gas Monitoring96 Questions
Exam 11: Sleep Diagnostics37 Questions
Exam 12: Introduction to Ventilators107 Questions
Exam 13: Mechanical Ventilators: General-Use Devices45 Questions
Exam 14: Infant and Pediatric Devices96 Questions
Exam 15: Transport, Home Care, and Noninvasive Ventilatory Devices52 Questions
Select questions type
Use of the Dräger E-4 nebulizer in the "Neo" setting will do which of the following?
Free
(Multiple Choice)
4.9/5
(75)
Correct Answer:
D
In the neonatal option,the Maquet Servoᶦ Ventilator has a maximum available flow of _____ L/min.
Free
(Multiple Choice)
4.8/5
(76)
Correct Answer:
C
The range of noninvasive ventilation nasal continuous positive airway pressure on the Maquet Servoᶦ Ventilator is _____ cm H₂O.
Free
(Multiple Choice)
4.8/5
(76)
Correct Answer:
B
What is the respiratory rate available on the CareFusion SiPAP?
(Multiple Choice)
4.8/5
(72)
When NeoFlow on the Dräger E-4 is activated,how much bias flow is initiated?
(Multiple Choice)
4.8/5
(81)
What range can be used for adjustment of peak flow when the CareFusion Avea is used for pediatric patients?
(Multiple Choice)
4.7/5
(82)
What is the breath termination for a CareFusion V.I.P.Bird Infant-Pediatric Ventilator set to deliver pressure support at tidal volume = 250 mL and peak expiratory flow 15 L/min?
(Multiple Choice)
4.8/5
(94)
A patient who weighs 4000 g is being ventilated by using a CareFusion AVEA Ventilator.How much volume will be lost in the tubing when the pressure is set at 15 cm H₂O?
(Multiple Choice)
4.8/5
(75)
The Bunnell Life Pulse High Frequency Jet Ventilator creates high-frequency jet ventilation by using which of the following mechanisms?
(Multiple Choice)
4.9/5
(88)
When helium/oxygen (heliox)is used with the CareFusion AVEA Ventilator in the infant/pediatric modes,which of the following statements is true?
(Multiple Choice)
4.7/5
(77)
When using the Dräger Evita XL,which of the following modes allow for the use of AutoFlow when the NeoFlow sensor is being used?
1)Continuous mandatory ventilation
2)Volume-assured pressure support
3)Synchronized intermittent mandatory ventilation
4)Mandatory minute ventilation
(Multiple Choice)
4.9/5
(89)
What is the minimum ideal body weight for ventilating an infant with a Puritan Bennett 840 with the NeoMode option?
(Multiple Choice)
4.8/5
(81)
When using the CareFusion V.I.P.Bird Gold Infant/Pediatric Ventilator with the infant flow sensor,the flow display comp button is pressed. The ventilator's monitor display window shows real-time inspiratory and expiratory flows of 9 L/min and 8.2 L/min.The most appropriate assist sensitivity control setting is ____ L/min.
(Multiple Choice)
4.8/5
(83)
NeoFlow on the Dräger E-4 is essential for infants with which of the following weights?
1)3.8 kg
2)5.0 kg
3)7.6 kg
4)8.4 kg
(Multiple Choice)
4.8/5
(83)
The purpose of the Venturi-type air amplifier on the CareFusion 3100A is to do which of the following?
(Multiple Choice)
4.8/5
(87)
The volume delivered by a time-triggered,pressure-limited,time-cycled infant ventilator depends directly on which of the following ventilator parameters?
1)Flow rate
2)Pressure limit
3)Respiratory rate
4)Inspiratory time
(Multiple Choice)
4.8/5
(84)
The respiratory therapist has determined that a 4.0-mm internal diameter standard endotracheal tube is necessary for the patient.What is the equivalent hi-lo jet tube to be used with a Bunnell Life Pulse High-Frequency Jet Ventilator?
(Multiple Choice)
4.7/5
(78)
At what point in the Bunnell Life Pulse High-Frequency Jet Ventilator,shown in the following figure,should a bacterial filter be placed?

(Multiple Choice)
4.9/5
(79)
The bias flow for the CareFusion V.I.P.Gold Ventilator when the Infant "Smart" Flow Sensor is in use is ____ L/min.
(Multiple Choice)
5.0/5
(80)
While a patient is being ventilated with NeoFlow on a Dräger E-4,an audible and visual alarm is active,and all breaths are being time-triggered. What is the most appropriate action for the respiratory therapist to take?
(Multiple Choice)
5.0/5
(74)
Showing 1 - 20 of 96
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)