Exam 15: Transport, Home Care, and Noninvasive Ventilatory Devices
Exam 1: Basic Physics for the Respiratory Therapist107 Questions
Exam 2: Principles of Infection Control95 Questions
Exam 3: Manufacture, Storage, and Transport of Medical Gases101 Questions
Exam 4: Administering Medical Gases: Regulators, Flowmeters, and97 Questions
Exam 5: Airway Management Devices and Advanced Cardiac Life Support70 Questions
Exam 6: Humidity and Aerosol Therapy88 Questions
Exam 7: Lung Expansion Therapy Devices57 Questions
Exam 8: Assessment of Pulmonary Function120 Questions
Exam 9: Assessment of Cardiovascular Function77 Questions
Exam 10: Blood Gas Monitoring96 Questions
Exam 11: Sleep Diagnostics37 Questions
Exam 12: Introduction to Ventilators107 Questions
Exam 13: Mechanical Ventilators: General-Use Devices45 Questions
Exam 14: Infant and Pediatric Devices96 Questions
Exam 15: Transport, Home Care, and Noninvasive Ventilatory Devices52 Questions
Select questions type
What is the tidal volume delivered when the Newport HT50 is set to deliver volume-controlled ventilation with an inspiratory time of 0.75 second and a flow of 0.83 L/s?
Free
(Multiple Choice)
4.9/5
(88)
Correct Answer:
B
The fractional inspired oxygen on a Dräger Carinahome ventilator is determined by which of the following?
Free
(Multiple Choice)
4.8/5
(90)
Correct Answer:
C
Which of the following is true concerning the difference between the Uni-Vent 750 and the Eagle 754?
Free
(Multiple Choice)
5.0/5
(71)
Correct Answer:
B
The Crossvent requires a compressed gas source of _________ to ensure adequate gas flow to the patient.
(Multiple Choice)
4.9/5
(86)
During the transport of a patient being ventilated with a Newport HT50 ventilator,the low airway pressure/apnea indicator begins to blink red and the "check proximal line" alarm is triggered. What is the most appropriate action?
(Multiple Choice)
4.9/5
(84)
Which of the following modes of operation are offered by the Airon pNeuton?
1)Volume-controlled intermittent mandatory ventilation
2)Pressure-controlled intermittent mandatory ventilation
3)Continuous positive airway pressure
4)Pressure-regulated volume control
(Multiple Choice)
4.8/5
(82)
What is the trigger variable for the Respironics BiPAP Focus?
(Multiple Choice)
4.8/5
(80)
What is the maximum length of an inspiratory hold on the Oxylog 3000 plus?
(Multiple Choice)
4.7/5
(80)
How is the minute ventilation high alarm (MVhigh)set on the Dräger Oxylog 3000?
(Multiple Choice)
4.8/5
(84)
The internal direct current battery of the Bio-Med Crossvent operates for approximately ____ hours.
(Multiple Choice)
4.9/5
(75)
The Dräger Oxylog 3000 can provide which of the following modes of operation?
1)Pressure-controlled ventilation+/pressure support
2)Continuous mandatory ventilation/continuous mandatory ventilationₐssᵢst
3)Pressure-regulated volume control
4)Control
(Multiple Choice)
4.9/5
(75)
A respiratory rate of 40 breaths/min is required to ventilate an infant with an MVP-10.The inspiratory and expiratory time settings that would provide 40 breaths/min are which of the following?
Inspiratory Time Expiratory Time
(Multiple Choice)
4.7/5
(79)
On the Smiths Medical Pneupac ventiPAC ventilator,which of the following would provide a 15 breaths/min respiratory rate?
(Multiple Choice)
5.0/5
(72)
The inspiratory-to-expiratory ratio would be 1:1.5 for _____ breaths/min on the Percussionaire Bronchotron TXP Ventilator.
(Multiple Choice)
4.9/5
(76)
Oxygen can be added to the Dräger Carinahome ventilator by which of the following methods?
(Multiple Choice)
4.9/5
(81)
Using the figure,what amount of oxygen is necessary to be bled into a Pulmonetic Systems LTV 1000,with a minute volume of 10 L/min,to achieve a fractional inspired oxygen level of 70%?

(Multiple Choice)
4.9/5
(82)
The large external battery that is used with the Pulmonetic Systems LTV 1000 ventilator lasts approximately ____ hours when fully charged.
(Multiple Choice)
4.8/5
(73)
What inspiratory flow and inspiratory time would produce a tidal volume of 750 mL on the Smiths Medical Pneupac ventiPAC ventilator?
Inspiratory flow Inspiratory time
1)0.33 L/s 1 s
2)0.5 L/s 1.5 s
3)0.75 L/s 1 s
4)0.45 L/s 2 s
(Multiple Choice)
4.8/5
(64)
Which of the following is a magnetic resonance imaging-compatible transport ventilator?
(Multiple Choice)
4.9/5
(71)
The estimated internal direct current battery on the Uni-Vent 750 can provide ____ hours of operation.
(Multiple Choice)
5.0/5
(76)
Showing 1 - 20 of 52
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)