Exam 13: Mechanical Ventilators: General-Use Devices
Exam 1: Basic Physics for the Respiratory Therapist107 Questions
Exam 2: Principles of Infection Control95 Questions
Exam 3: Manufacture, Storage, and Transport of Medical Gases101 Questions
Exam 4: Administering Medical Gases: Regulators, Flowmeters, and97 Questions
Exam 5: Airway Management Devices and Advanced Cardiac Life Support70 Questions
Exam 6: Humidity and Aerosol Therapy88 Questions
Exam 7: Lung Expansion Therapy Devices57 Questions
Exam 8: Assessment of Pulmonary Function120 Questions
Exam 9: Assessment of Cardiovascular Function77 Questions
Exam 10: Blood Gas Monitoring96 Questions
Exam 11: Sleep Diagnostics37 Questions
Exam 12: Introduction to Ventilators107 Questions
Exam 13: Mechanical Ventilators: General-Use Devices45 Questions
Exam 14: Infant and Pediatric Devices96 Questions
Exam 15: Transport, Home Care, and Noninvasive Ventilatory Devices52 Questions
Select questions type
Which of the following ventilators can be used during magnetic resonance imaging?
Free
(Multiple Choice)
4.9/5
(74)
Correct Answer:
C
Which of the following on a Dräger Evita XL is considered to be a dual control mode?
Free
(Multiple Choice)
4.7/5
(78)
Correct Answer:
B
What is meant by the term "proportional pressure support" on a Dräger V500?
Free
(Multiple Choice)
5.0/5
(75)
Correct Answer:
A
What level of pressure support is available on the GE Carestation?
(Multiple Choice)
4.9/5
(99)
Which of the following statements best describes the volume support mode on the Covidien PB 840?
(Multiple Choice)
4.9/5
(78)
What modes of ventilation on the Dräger V500 allow for the use of autoflow?
(Multiple Choice)
4.7/5
(78)
What range of pressure support is available on the Covidien PB 840?
(Multiple Choice)
4.8/5
(67)
What is the range for setting the level of flow trigger on the Hamilton G5?
(Multiple Choice)
4.8/5
(69)
Which of the following statements best describes automode on the Maquet Servoᶦ?
(Multiple Choice)
4.8/5
(64)
Which of the following can be monitored with the Maquet Servoᶦ?
1)Inspiratory and expiratory resistance
2)Patient work of breathing
3)Work of breathing associated with the ventilator
4)Electrical activity of the diaphragm
(Multiple Choice)
4.7/5
(87)
What is the range for expiratory trigger sensitivity on the Hamilton G5?
(Multiple Choice)
4.8/5
(72)
Which of the following can be monitored with the Covidien PB 840?
1)Leak flow and volume
2)Dynamic compliance and airway resistance
3)Work of breathing during proportional assist ventilation
4)Peak spontaneous flow
(Multiple Choice)
4.8/5
(84)
What is the range for adjustment of the inspiratory pressure on the Covidien PB 840?
(Multiple Choice)
4.8/5
(84)
The Carefusion Avea ventilator is being used during transport; the electrical power source in the ambulance fails.How long will the internal power source allow the ventilator to function?
(Multiple Choice)
4.8/5
(83)
What positive end-expiratory pressure levels are available on the Dräger V500?
(Multiple Choice)
4.8/5
(93)
What is the available range for tidal volume when the CareFusion AVEA is used in the adult mode?
(Multiple Choice)
4.9/5
(74)
At what point in the ventilatory cycle is auto-PEEP measured on a Dräger EvitaXL?
(Multiple Choice)
4.8/5
(72)
How long does the internal battery of the CareFusion AVEA power the ventilator and compressor?
(Multiple Choice)
4.8/5
(87)
Showing 1 - 20 of 45
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)