Exam 13: Mechanical Ventilators: General-Use Devices

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Which of the following respiratory mechanics can be measured with the CareFusion AVEA? 1)Esophageal pressure measurement 2)Peak inspiratory pressure/P₁₀₀ 3)Inflection point 4)Auto-PEEP

(Multiple Choice)
4.7/5
(73)

What is the maximum pressure limit in the CareFusion AVEA?

(Multiple Choice)
4.9/5
(72)

Which of the following is (are)used in the measurement of tidal volume on a CareFusion AVEA ventilator? 1)Variable-orifice pneumotachometer 2)Pressure differential pneumotachometer 3)Ultrasonic flow sensor 4)Hot wire flow sensing device

(Multiple Choice)
4.9/5
(71)

Which of following parameters are measured and displayed on the user interface of a Hamilton G5? 1)Auto-PEEP 2)Peak inspiratory pressure 3)Mean airway pressure 4)Expired minute volume 5)Static compliance

(Multiple Choice)
4.8/5
(86)

What is the range for trigger sensitivity on the Dräger EvitaXL?

(Multiple Choice)
5.0/5
(81)

When proportional assist ventilation is used on the Covidien PB 840,what percentage of support is available?

(Multiple Choice)
4.9/5
(77)

Which of the following statements best describes the use of adaptive pressure ventilation on the Hamilton G5?

(Multiple Choice)
4.9/5
(84)

What modes of ventilation on the CareFusion AVEA provide apnea backup ventilation? 1)Volume assist/control 2)Volume synchronized intermittent mandatory ventilation 3)Airway pressure release ventilation/biphasic 4)Continuous positive airway pressure/pressure support ventilation

(Multiple Choice)
4.8/5
(88)

Which of the following statements best describes the application of the Open Lung Tool on the Maquet Servoᶦ?

(Multiple Choice)
4.8/5
(93)

Which of the following statements best describes the function of proportional assist ventilation on the Covidien PB 840?

(Multiple Choice)
4.7/5
(83)

What is the range for adjustment of the expiratory sensitivity on the Covidien PB 840?

(Multiple Choice)
4.9/5
(107)

What is the range for the delivered tidal volume for an adult on the Dräger EvitaXL?

(Multiple Choice)
4.8/5
(80)

What range of pressure can be displayed on the user interface on the Covidien PB 840?

(Multiple Choice)
5.0/5
(85)

What mixture of helium:oxygen can be administered with the CareFusion AVEA?

(Multiple Choice)
4.9/5
(83)

Which of the following is the available range for pressure support on the Maquet Servoᶦ?

(Multiple Choice)
4.7/5
(64)

What mode of ventilation is used on the Dräger V500 to provide a minimum expired volume?

(Multiple Choice)
4.9/5
(80)

What is the range for the tidal volume on the Maquet Servoᶦ?

(Multiple Choice)
4.9/5
(76)

When an inspiratory pause is used on a Hamilton G5,what is the percentage of the cycle time it can be set for?

(Multiple Choice)
4.7/5
(82)

What is the available range for the respiratory rate when the Maquet Servoᶦ is used in the continuous mandatory ventilation mode?

(Multiple Choice)
4.7/5
(69)

Which of the following statements describes how a sigh breath is delivered on an Dräger Evita XL ventilator?

(Multiple Choice)
5.0/5
(71)
Showing 21 - 40 of 45
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)