Exam 14: Infant and Pediatric Devices

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Which of the following actions will maximize the life of the oscillator mechanism on a CareFusion 3100A High-frequency Oscillatory Ventilator?

(Multiple Choice)
4.8/5
(77)

The "jet valve fault" alarm is active on a Bunnell Life Pulse High-Frequency Jet Ventilator.This problem can be corrected by doing which of the following?

(Multiple Choice)
4.9/5
(77)

The "cannot meet PIP" alarm is active on a Bunnell Life Pulse High-Frequency Jet Ventilator.The respiratory therapist should do which of the following? 1)Check the humidifier cartridge for a leak. 2)Check the jet tube connection to the circuit. 3)Look for kinks in the jet tube connections. 4)Check the dump valve for proper function.

(Multiple Choice)
4.9/5
(61)

The oxygen concentration alarm limits on the Dräger Babylog 8000 are set _____ at _____ of the setting.

(Multiple Choice)
4.9/5
(78)

How many cycles per minute is 15 Hz?

(Multiple Choice)
4.8/5
(78)

Which of the following is not true of the Hamilton ARABELLA System?

(Multiple Choice)
5.0/5
(78)

Which of the following events occur when the mean airway pressure exceeds 50 cm H₂O?

(Multiple Choice)
4.8/5
(67)

What is the amount of pressure drop required to initiate the leak-compensation feature on the CareFusion V.I.P.Bird Infant-Pediatric Ventilator during the volume-cycled mode?

(Multiple Choice)
4.9/5
(76)

The Bunnell Life Pulse High-Frequency Jet Ventilator is being set up to ventilate an infant who has a regular endotracheal tube with a 3.5-mm internal diameter Life Port adapter.Conventional peak inspiratory pressure is set at 30 cm H₂O.The high-frequency jet ventilation peak inspiratory pressure should be set at a pressure of _____ cm H₂O.

(Multiple Choice)
4.9/5
(86)

The recommended flow rate range for the Fisher & Paykel Healthcare Bubble CPAP System is _____ L/min.

(Multiple Choice)
4.9/5
(93)

A trigger sensitivity setting of 1 on a Dräger Babylog 8000 Infant Ventilator indicates ____ trigger.

(Multiple Choice)
4.8/5
(75)

During infant ventilation with the CareFusion AVEA Ventilator and the Cosmo Plus Monitor,the readings on the Cosmo Plus Monitor have "blanked out." What is the cause of this problem?

(Multiple Choice)
4.9/5
(91)

If a pressure-support breath on a CareFusion V.I.P.Bird Infant-Pediatric Ventilator is 25 mL and the peak inspiratory flow is 10 L/min,the breath will flow-cycle at _____ L/min.

(Multiple Choice)
4.8/5
(84)

Which of the following statements concerning the use of AutoFlow for neonates on the Dräger E-4 is true?

(Multiple Choice)
4.8/5
(80)

What is the maximum amount of time an alarm condition must persist on the CareFusion Infant Flow Nasal CPAP System for an alarm to be delayed when the ventilator is being set up?

(Multiple Choice)
4.8/5
(69)

Which of the following statements concerning the CareFusion/Infant Flow SiPAP Comprehensive System is not true?

(Multiple Choice)
4.8/5
(94)

On a Dräger E-4 operating in NeoFlow,which of the following trigger ranges is recommended for neonatal and pediatric ventilation?

(Multiple Choice)
4.8/5
(80)

The volume delivered by a time-triggered,pressure-limited,time-cycled infant ventilator is dependent on which of the following factors? 1)Positive end-expiratory pressure level 2)Airway resistance 3)Lung compliance 4)Chest wall compliance

(Multiple Choice)
4.8/5
(82)

Which of the following units is able to provide more support than traditional noninvasive continuous positive airway pressure to transition infants and pediatric patients from intubation to successful extubation?

(Multiple Choice)
4.9/5
(78)

NeoFlow on a Dräger E-4 requires the installation of a flow sensor into which part of the patient circuit?

(Multiple Choice)
4.9/5
(76)
Showing 21 - 40 of 96