Exam 14: Infant and Pediatric Devices

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

Increasing the bias flow on the CareFusion 3100A High-frequency Oscillatory Ventilator would cause which of the following to occur?

(Multiple Choice)
4.8/5
(93)

Which of the following statements concerning the use of the Fisher & Paykel Healthcare Bubble CPAP System is true?

(Multiple Choice)
4.8/5
(78)

The maximum number of hours that the CareFusion AirLife Nasal CPAP System Driver can display trend data is _____ hours.

(Multiple Choice)
4.9/5
(86)

What is the available range for setting the respiratory rate on the Covidien PB 840 Ventilator when it is used in the NeoMode?

(Multiple Choice)
4.9/5
(87)

Which of the following statements is true concerning the CareFusion AirLife Nasal CPAP System Driver?

(Multiple Choice)
4.9/5
(80)

When is the oxygen blender on the CareFusion Infant Flow Nasal CPAP System recalibrated?

(Multiple Choice)
4.7/5
(74)

The termination sensitivity control on the Care Fusion V.I.P.Bird Infant-Pediatric Ventilator does which of the following?

(Multiple Choice)
4.7/5
(75)

There is a 3-L/min leak around the nasal prongs during nasal continuous positive airway pressure on the Maquet Servoᶦ Ventilator.This will cause which of the following?

(Multiple Choice)
4.9/5
(84)

Which of the following statements concerning the CareFusion 3100A and 3100B is true?

(Multiple Choice)
4.9/5
(74)

On a Dräger Babylog 8000,which of the following variables can trigger mandatory breaths in the synchronized intermittent mandatory ventilation mode?

(Multiple Choice)
4.7/5
(79)

A pediatric patient is being ventilated with a CareFusion V.I.P.Bird Gold Infant/Pediatric Ventilator in the assist/control volume mode with appropriately set trigger sensitivity.Physical assessment of the patient reveals the use of accessory muscles during patient triggering.What is the most appropriate action?

(Multiple Choice)
4.8/5
(81)

Heliox delivery is available through which of the following ventilators?

(Multiple Choice)
4.9/5
(91)

Circuit positive end-expiratory pressure may be avoided by using:

(Multiple Choice)
4.8/5
(82)

With a CareFusion V.I.P.Bird Infant-Pediatric Ventilator,a flashing pressure-support display during spontaneous breathing can be caused by which of the following?

(Multiple Choice)
4.9/5
(80)

The stable jet flow from the ARABELLA System causes which of the following?

(Multiple Choice)
4.9/5
(65)

In the neonatal option,the Maquet Servoᶦ Ventilator has a bias flow of _____ L/min.

(Multiple Choice)
4.8/5
(73)

The range of continuous positive airway pressure that the Fisher & Paykel Healthcare Bubble CPAP System can provide is _____ cm H₂O.

(Multiple Choice)
4.9/5
(84)

Which of the following mechanisms is incorporated into the CareFusion V.I.P.Bird Infant-Pediatric Ventilator to prevent the risk of auto-PEEP during ventilation with the time-cycled modes?

(Multiple Choice)
4.9/5
(70)

The jet rate range for the Bunnell Life Pulse High-Frequency Jet Ventilator is _____ insufflations/min.

(Multiple Choice)
4.9/5
(70)

A pressure-support breath on a CareFusion V.I.P.Bird delivers 230 mL,and the peak inspiratory flow is 18 L/min.This breath will flow-cycle at _____ L/min.

(Multiple Choice)
4.8/5
(88)