Exam 25: Gas Chromatography

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

The first 3 to 10 meters of a capillary column serves as a guard column and retention gaps.Guard columns:

Free
(Multiple Choice)
4.9/5
(91)
Correct Answer:
Verified

C

To maximize solid-phase microextraction analyte recovery,keep all of the following in mind,except:

Free
(Multiple Choice)
4.8/5
(80)
Correct Answer:
Verified

E

As the temperature of a GC column increases,the____________________ of the analytes increases,the retention time________________________________________and the peak shapes____________________ .

Free
(Multiple Choice)
4.8/5
(76)
Correct Answer:
Verified

C

Which is NOT true for split injection?

(Multiple Choice)
4.7/5
(62)

To quantify the amount of ethanol in an organic sample,a technician prepares a standard solution containing 0.1473 grams ethanol and 0.1847 grams decane in 1.203 grams dichlormethane.GC analysis returns peak areas of 9,930 for ethanol and 7,893 for decane.Next,0.9831 grams unknown and 0.2932 grams decane are added to 1.2119 grams dichloromethane.GC analysis returns peak areas of 6,382 for ethanol and 11,283 for decane.What is the percent by mass ethanol in the sample?

(Short Answer)
4.9/5
(80)

Which statement is NOT true for GC carrier gases?

(Multiple Choice)
4.9/5
(59)

Which of the following statements are true for GC columns? I GC columns are capillaries composed of fused silica and coated with a polyimide. II Column inner diameters are typically 0.10 cm to 0.53 cm and the columns are 15 cm to 100 cm in length,with 30 cm the most common. III A wall-coated open tubular column has a liquid stationary phase coating the inside wall of the column. IV A porous-layer column is filled with a highly porous stationary phase. V A packed column is a column filled with a solid stationary support coated in liquid stationary phase.

(Multiple Choice)
4.9/5
(75)

Which statement is NOT true for gas chromatography detectors?

(Multiple Choice)
4.7/5
(84)

Which statement is NOT true for flame ionization detectors?

(Multiple Choice)
4.9/5
(83)

For method development,multiple decisions must be made.Order the development decisions below in the proper order. I detector II goal of analysis III injection IV sample preparation V column

(Multiple Choice)
4.8/5
(71)

____________________ columns are used with____________________ chromatography.

(Multiple Choice)
5.0/5
(68)

For quantitative analysis with gas chromatography:

(Multiple Choice)
4.7/5
(68)

The response factor between an alcohol and an alkane is 2.54.An internal standard with a concentration of 25.9 nM has a peak area of 92832.The peak area for the alcohol is 23422.What is the concentration of alcohol in the sample?

(Short Answer)
4.9/5
(71)

The thermal conductivity detector functions by measuring the________________________________________for a hot filament that is the result of a(n)____________________ to compensate for the____________________ of the filament by the mixture of analyte and carrier gas that elutes from the column.

(Multiple Choice)
4.8/5
(70)

Under what conditions are split,splitless,and on-column injection used? I Split injection is preferred for samples where the analyte of interest constitute > 0.1% of the sample. II On-column injection is used for samples that decompose above their boiling point. III Splitless injection is preferred for introducing small volumes of sample onto the column. IV Split injection is preferred for samples with high boiling point solutes in low boiling point solvents. V Splitless injection is preferred for trace analysis of analytes that are less than 0.01% of the sample.

(Multiple Choice)
4.8/5
(73)

Cold trapping and solvent trapping is used with____________________ injection to give____________________ peaks.

(Multiple Choice)
4.8/5
(87)

The elution order for solutes from a gas chromatography column is loosely in order of:

(Multiple Choice)
4.9/5
(84)

Which of the following is INCORRECT for quantitative or qualitative analysis with gas chromatography?

(Multiple Choice)
4.8/5
(76)

Which is NOT a sample preparation technique for use with gas chromatography?

(Multiple Choice)
4.8/5
(74)

The temperature program for a separation starts at a temperature of 50 oC and ramps the temperature up to 270 oC at a rate of 10 oC/minute.Which statement is NOT true for this separation?

(Multiple Choice)
5.0/5
(77)