Exam 21: Spectrophotometers
Exam 1: The Analytical Process20 Questions
Exam 2: Chemical Measurements21 Questions
Exam 3: Tools of the Trade19 Questions
Exam 4: Experimental Error20 Questions
Exam 5: Statistics22 Questions
Exam 6: Quality Assurance and Calibration Methods20 Questions
Exam 7: Chemical Equilibrium20 Questions
Exam 8: Let the Titrations Begin20 Questions
Exam 9: Activity and the Systematic Treatment of Equilibrium20 Questions
Exam 10: Monoprotic Acid-Base Equilibria20 Questions
Exam 11: Polyprotic Acid-Base Equilibria20 Questions
Exam 12: Acid-Base Titrations20 Questions
Exam 13: Edta Titrations20 Questions
Exam 14: Advanced Topics in Equilibrium20 Questions
Exam 15: Fundamentals of Electrochemistry20 Questions
Exam 16: Electrodes and Potentiometry20 Questions
Exam 17: Redox Titrations20 Questions
Exam 18: Electroanalytical Techniques20 Questions
Exam 19: Fundamentals of Spectrophotometry23 Questions
Exam 20: Applications of Spectrophotometry20 Questions
Exam 21: Spectrophotometers20 Questions
Exam 22: Atomic Spectroscopy20 Questions
Exam 23: Mass Spectrometry20 Questions
Exam 24: Introduction to Analytical Separations20 Questions
Exam 25: Gas Chromatography20 Questions
Exam 26: High-Performance Liquid Chromatography20 Questions
Exam 27: Chromatographic Methods and Capillary Electrophoresis20 Questions
Exam 28: Gravimetric and Combustion Analysis20 Questions
Exam 29: Sample Preparation19 Questions
Select questions type
Which statement(s)is(are)true for photomultiplier tubes?
I Photomultiplier tubes are very sensitive detectors,amplifying the photoelectron current by approximately 1 million.
II Emitted photoelectrons are accelerated toward positively charged electrodes called dynodes.
III Electrons strike the dynode with a kinetic energy less than the original emitted kinetic energy.
IV For each electron striking a dynode,more than one electron is knocked free.The additional electrons are accelerated toward the next dynode in the detector where amplification is repeated.
Free
(Multiple Choice)
4.8/5
(79)
Correct Answer:
D
____________________ response is a function of incident light and produce an electrical current when struck by .For a given radiant power,current is____________________ analyte concentration.
Free
(Multiple Choice)
4.8/5
(84)
Correct Answer:
B
The monochromator for a new instrument design must successfully resolve 0.005 nm at 631 nm.Calculate the minimum number of grooves per centimeter for the diffraction grating if the grating has a length of 5 cm.Assume first order diffraction.
Free
(Short Answer)
4.9/5
(66)
Correct Answer:
25240
Calculate the minimum grating length to successfully resolve 616.50 nm from 616.59 nm for first-order diffraction.The available diffraction grating is 103 grooves per cm.
(Multiple Choice)
4.7/5
(93)
There are many types of noise.Of the noise types below,which is NOT correctly defined?
(Multiple Choice)
4.8/5
(87)
The true absorbance for a 1.0 x 10−5 M solution is 0.7526.If the percentage stray light for a spectrophotometer is 0.56%,calculate the percentage by which the apparent concentration deviates from the known concentration.
(Short Answer)
4.8/5
(72)
Which statements are true for optical fibers?
I Optical fibers carry light by total internal refraction.
II Optical fibers are constructed of a high-refractive-index transparent core enclosed in a lower refractive-index transparent cladding.
III Optical fibers exploit Snells Law,n1 sin 1 = n2 sin 2,to transmit light along the length of the optical fiber.
IV If n1/n2 < 1,there is an allowed range of angles i in which essentially all light is reflected at the walls of the core,with negligible amounts of light penetrating the cladding.
(Multiple Choice)
4.9/5
(83)
Which property of noise does signal averaging exploit to improve the signal-to-noise ratio?
(Multiple Choice)
4.8/5
(78)
Spectrophotometers employ various sources of light.Which of the following is NOT true for spectrophotometer light sources?
(Multiple Choice)
4.8/5
(74)
Which property of laser light is NOT correctly defined/described?
(Multiple Choice)
4.8/5
(86)
Stray light is a problem for spectrophotometers that are not tightly sealed.What is the impact of stray light on the recorded absorbance?
(Multiple Choice)
4.9/5
(79)
Ni emits light at 345.85 nm and 346.17 nm in an atomic emission spectrophotometer.Can the spectrophotometer's monochromator successfully resolve 345.85 nm from 346.17 nm? The grating has a length of 5.0 cm in length and there are 5500 grooves per cm.Assume first-order diffraction.
(Essay)
4.9/5
(82)
A____________________ disperses light into its component wavelengths and selects a narrow band of wavelengths to pass on to the sample or detector.
(Multiple Choice)
4.8/5
(71)
Which of the following monochromator terms is NOT correctly defined?
(Multiple Choice)
4.9/5
(74)
Which is NOT an appropriate detector for a spectrophotometer?
(Multiple Choice)
4.8/5
(79)
____________________ are optical sensors based on an optical fiber.
(Multiple Choice)
4.9/5
(83)
The signal-to-noise ratio for a single spectrum is 2.18.How many additional scans are required to increase the signal-to-noise ratio by a factor of 50?
(Short Answer)
4.9/5
(72)
Two components of an interferometer are a moveable mirror and a beam splitter.Which of the following are NOT true statements regarding each component in creating an interferogram?
I When the mirror travels a distance of /4,deconstructive interference occurs.
II The beam splitter alternates the incident light between a reference and the sample.
III When the mirror travels a distance of /2,deconstructive interference occurs.
IV The beam splitter splits the incident light between the stationary mirror and the moveable mirror.
(Multiple Choice)
4.9/5
(61)
Which of the following statements regarding double beam spectrophotometers is NOT true?