A security program consists of three independent components. They are electronic, architectural, and:

(Multiple Choice)
4.9/5
(85)

You are designing an audible alarm notification system for an office environment with an ambient noise level of 55 dBA. What dBA level should the horn be set at?

(Multiple Choice)
4.8/5
(86)

A reasonable approximation for the signal speed in 100 ohm balanced twisted pair cable is __________, where c is the velocity of light in free space.

(Multiple Choice)
4.8/5
(86)

You are placing Category 6 unshielded twisted-pair (UTP) in cable tray down a hallway past the elevator mechanical room. What action should you take to avoid effects of electromagnetic interference (EMI)?

(Multiple Choice)
4.9/5
(71)

If you have a 30 cm (12 in) wide data tray, what does ANSI/TIA 569-B recommend be the maximum pathway fill cross sectional area assuming a MAXIMUM pathway depth of 15 cm (6 in)?

(Multiple Choice)
4.9/5
(86)

The recommended MAXIMUM value for the bonding resistance between the nearest available grounding electrode and the busbar in an entrance facility (EF) is ________ ohms.

(Multiple Choice)
4.9/5
(73)

You have been asked to design a public safety microwave radio system for the city of Fairbanks, Alaska. The requirement for reliability, maximum throughput, and minimum interference by fog, rain, or heavy snow is critical. Which frequency will best suit the system's needs?

(Multiple Choice)
4.9/5
(84)

In a telecommunication room (TR), the ________ is the facility used to make cross connections from the backbone cable to the horizontal cable.

(Multiple Choice)
4.8/5
(80)

You are designing the cabling infrastructure for a lab office building that will frequently change tenants. The owner will be responsible for all of the infrastructure that feeds each floor to include the telecommunication rooms. Which firestop method will best suit the owners needs?

(Multiple Choice)
4.9/5
(97)

The information technology system (ITS) designer should design conduits entering a building from ceiling height to terminate ________ below the finished ceiling.

(Multiple Choice)
4.8/5
(95)

Assume that the optical power transmitted by a 62.5/125 multimode fiber is distributed uniformly across its core. If this fiber is perfectly coupled (i.e., the two fibers are aligned and abutted) to a 50/125 fiber, what is the percent of power that is lost?

(Multiple Choice)
4.9/5
(70)

Vertical conduit masts (with approved service heads) are limited to drop-wire attachments of up to ________ lines.

(Multiple Choice)
4.8/5
(73)

Which of the following electrical devices is used to convert AC to DC?

(Multiple Choice)
4.9/5
(74)

The MINIMUM dimensions of the telecommunications main grounding busbar is ________ and variable in length.

(Multiple Choice)
4.8/5
(91)

You have just finished a design calling for 15 telecommunications outlets. You received word that the owner has increased his requirements by 40%. What size commercial DD (distribution device) is required to accommodate the increase?

(Multiple Choice)
4.7/5
(84)

Composite conductors, although not generally recommended, may be used in special circumstances because they provide all of the following advantages EXCEPT:

(Multiple Choice)
4.8/5
(69)

IPv-4 addresses are ________ bits in length.

(Multiple Choice)
4.9/5
(76)

Which service is NOT typical of Grade 1?

(Multiple Choice)
4.8/5
(94)

A telecommunications outlet/connector may be provided using all listed below EXCEPT:

(Multiple Choice)
4.7/5
(79)

When designing a backbone distribution system, you will need to include a telecommunications enclosure (TE). A TE can be defined as a:

(Multiple Choice)
4.9/5
(88)