Exam 1: BICSI Registered Communications Distribution Designer - RCDD

arrow
  • Select Tags
search iconSearch Question
flashcardsStudy Flashcards
  • Select Tags

All of the following are true about the post construction phase EXCEPT:

(Multiple Choice)
4.7/5
(65)

Which characteristic is an advantage of copper based media over optical fiber cable?

(Multiple Choice)
5.0/5
(75)

Electrical power cables are usually routed above aerial cable in order to:

(Multiple Choice)
4.7/5
(76)

Given the following values, calculate the focal length of the camera lens. - Distance of the camera to the object is 5 m - Vertical field of view is 2 m - Horizontal field of view 1 m

(Multiple Choice)
4.9/5
(78)

The RECOMMENDED balanced twisted-pair cable for building backbone cabling consists of ________ round solid copper conductors with a nominal characteristic of 100 ohm.

(Multiple Choice)
4.8/5
(81)

You have been asked to spec the physical security requirements related to the protection of assets for a new data center. The most common potential for damage categories you have considered include temperature, gases, organisms and projectiles. The one category that you have missed is:

(Multiple Choice)
4.8/5
(88)

A tapped trunk topology uses ________ cabling to support a DAS.

(Multiple Choice)
4.8/5
(92)

All of the following are nominal wavelengths for laser light sources EXCEPT:

(Multiple Choice)
4.7/5
(86)

You are placing an entrance cable between two buildings connected by a conduit 205.3 m (588 ft) in length. What would be the MAXIMUM length of unlisted OSP cable that could be used before you terminate the cable or transition it to a listed cable?

(Multiple Choice)
4.9/5
(89)

The public telephone system is an example of a __________ system.

(Multiple Choice)
4.8/5
(69)

Often associated with raised flooring, a(n) ________ may consist of copper straps taped to the concrete floor, or it may be the floor itself with the stringers that support the tiles acting as the bonding conductor across the gradient of the floor.

(Multiple Choice)
4.8/5
(80)

Which of the following is true about screened twisted pair cable assemblies?

(Multiple Choice)
4.8/5
(85)

Which is NOT true about conformance quality?

(Multiple Choice)
4.9/5
(80)

Important considerations when designing telecommunications distribution within modular furniture include all of the following EXCEPT:

(Multiple Choice)
4.9/5
(87)

To reduce the chance of an accidental dig-up, plastic warning tape should be placed a MINIMUM of _________ below grade, but high enough above cables to allow detection before cables are damaged.

(Multiple Choice)
4.8/5
(83)

You have been selected to do the telecommunications design on a new, single story building. The architect requires the size and location of the telecommunications rooms so their building design can proceed. From the items listed below (all of which are required for the design), which one is the logical starting point in order to provide the architect with a size and location for the room?

(Multiple Choice)
4.8/5
(90)

Color codes for cross-connections fields have been used for many years. Which color is used to identify horizontal cable?

(Multiple Choice)
4.9/5
(83)

The purpose of QoS on an IP network is for:

(Multiple Choice)
4.9/5
(76)

The F rating for a framed wall/stud wall is ________ hour(s).

(Multiple Choice)
4.9/5
(80)

In an industry where a high level of humidity is measured, which type of label should be used?

(Multiple Choice)
4.8/5
(76)
Showing 81 - 100 of 340
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)