Exam 1: BICSI Registered Communications Distribution Designer - RCDD
Exam 1: BICSI Registered Communications Distribution Designer - RCDD340 Questions
Select questions type
Which device uses circulators or diplexer filters to separate and combine the different transmit and receive RF paths?
(Multiple Choice)
4.7/5
(83)
The propagation and path loss of radio signals in the target environment can be sampled using:
(Multiple Choice)
4.9/5
(78)
You have been selected to recommend a solution to increase response time and add fault tolerance to a bank of servers. Your budget is limited and the client needs a solution as soon as possible (ASAP). Which of the following options should be considered with the short time frame and limited budget?
(Multiple Choice)
4.8/5
(75)
Which layer of the OSI model covers physical cable connections?
(Multiple Choice)
4.7/5
(74)
As a guide, the MAXIMUM recommended DC current value on any bonded conductor should be less than:
(Multiple Choice)
4.9/5
(85)
Exhibit: The diagram below is a typical configuration for: 
(Multiple Choice)
4.8/5
(72)
Which of the following is NOT a primary method of transporting radio signals in an active DAS?
(Multiple Choice)
4.9/5
(75)
A conduit run is installed from the ER to a TR. It has two (2) 90 degree bend and a length of 20 m (65 ft). What will be the MINIMUM test rating of the pull cord left in the conduit?
(Multiple Choice)
4.9/5
(86)
From a 1000 ft (305 m) roll of optical fiber, how many MAXIMUM length centralized optical fiber cabling runs can be made?
(Multiple Choice)
4.9/5
(78)
At the end of the third week of a project, the actual cost of work performed is $7000 USd and the budgeted cost of work performed is $8000 USd. Which of the following is true?
(Multiple Choice)
4.8/5
(62)
Which of the following is NOT a type of intrusion detection system sensor?
(Multiple Choice)
4.8/5
(73)
Which of the following is NOT an example of a perimeter pathway?
(Multiple Choice)
4.8/5
(84)
The impedance of the equipment grounding conductor can only be accurately measured with an instrument known as a(n):
(Multiple Choice)
4.8/5
(90)
You have been asked to design a backbone cable connecting two large campus buildings. Your pathways will include using conduits, maintenance holes, and one section of 100 m (328 ft) of direct buried optical fiber cable. Your choice of fiber optic cable type recommendation is a:
(Multiple Choice)
4.9/5
(79)
Exhibit:
In this future marina layout, assuming that there are fewer than 10 slips being cabled, what would be the pre-cabling guideline to follow for terminal A?
(Multiple Choice)
4.9/5
(86)
When allocating termination space for CAT 6 and optical fiber cables, it is recommended that additional space of up to ________ percent be considered for the routing of the cables and patch cords.
(Multiple Choice)
4.9/5
(71)
Optical transmitters are typically one of the following types EXCEPT:
(Multiple Choice)
4.8/5
(70)
Showing 241 - 260 of 340
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)