Exam 1: BICSI Registered Communications Distribution Designer - RCDD
Exam 1: BICSI Registered Communications Distribution Designer - RCDD340 Questions
Select questions type
Which class of the system was created to secure a single equipment room (ER)?
(Multiple Choice)
4.9/5
(76)
You are designing a cabling system for a chemical plant. What type of device is needed to prevent the spread of fire along the cable other than the barrier penetrations?
(Multiple Choice)
4.8/5
(63)
If the usable floor space is unknown, then deduct ________ percent of the total area available to estimate the usable area.
(Multiple Choice)
4.7/5
(85)
You are given a choice of methods of routing backbone cabling vertically through a building. The one option that you do NOT want to use is:
(Multiple Choice)
4.7/5
(86)
In (ESS) design, employees, reputation, and materials are all examples of:
(Multiple Choice)
4.9/5
(76)
Geographically speaking, a __________ covers an area associated with an individual's work space.
(Multiple Choice)
4.9/5
(77)
ITU-T G.655 recommends which type of singlemode optical fiber?
(Multiple Choice)
4.8/5
(86)
Based on documentation contained within the Insulated Cable Engineers Association (ICEA) standard P32-382, Short Circuit Characteristics of Insulated Cable, a copper conductor is capable of safely carrying one ampere for ________ second(s) for every 42.25 circular mils.
(Multiple Choice)
4.8/5
(88)
Which electrical characteristic is displayed with the correct preferred value?
(Multiple Choice)
4.8/5
(84)
You are designing a building with a combination of Class A commercial office spaces and residences. The design program requires having unlimited cable channels available at all outlet locations. What distribution system topology will NOT provide adequate channel distribution to each location?
(Multiple Choice)
4.9/5
(95)
What device is used in both wired and wireless networks to link network access devices?
(Multiple Choice)
4.8/5
(81)
For the telecommunications industry, the nominal operating voltage is ________ volts DC.
(Multiple Choice)
4.9/5
(96)
The information technology system (ITS) designer should design conduits entering a building from below grade point to extend ________ above finished floor (AFF).
(Multiple Choice)
4.9/5
(69)
The standard floor space coverage area for each building automation system (BAS) is a BAS outlet or device for every ________ of floor space.
(Multiple Choice)
4.8/5
(78)
Within a data center, how many concentric layers are considered necessary to provide effective security?
(Multiple Choice)
4.9/5
(89)
A ______ intercepts a file and stores it temporarily in queue until a peripheral device (e.g. printer) is available.
(Multiple Choice)
4.8/5
(72)
Which one of the following is part of the security metric to consider in selecting the appropriate labels for an administrative system?
(Multiple Choice)
4.8/5
(77)
Assuming the total fill capacity of a pathway is 100 cables (all of the same cable type and size), the MAXIMUM number of cables to be installed during the initial installation, without exceeding the fill ratio is:
(Multiple Choice)
4.8/5
(71)
An outside plant (OSP) cable must be placed under a pipeline with two side by side pipe runs. The distance between the outside pipes is 6 m (20 ft). What is the length of the conduit required to facilitate the pipeline crossing?
(Multiple Choice)
4.9/5
(66)
A building has six floors plus a basement. Each floor is 929 sq m (10,000 sq ft) and has approximately 50 CATV outlets respectively. There is a single hardline trunk cable installed from the basement headend passing through the telecommunications room (TR) on each floor. In order to maintain the LEAST signal loss passing through each telecommunications room (TR) to the next telecommunications room (TR), what device should you specify for use within each telecommunications room (TR)?
(Multiple Choice)
4.9/5
(76)
Showing 281 - 300 of 340
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)