Question 81
Multiple Choice
All of the following are true about the post construction phase EXCEPT:
Question 82
Multiple Choice
Which characteristic is an advantage of copper based media over optical fiber cable?
Question 83
Multiple Choice
Electrical power cables are usually routed above aerial cable in order to:
Question 84
Multiple Choice
Given the following values, calculate the focal length of the camera lens. - Distance of the camera to the object is 5 m - Vertical field of view is 2 m - Horizontal field of view 1 m
Question 85
Multiple Choice
The RECOMMENDED balanced twisted-pair cable for building backbone cabling consists of ________ round solid copper conductors with a nominal characteristic of 100 ohm.
Question 86
Multiple Choice
You have been asked to spec the physical security requirements related to the protection of assets for a new data center. The most common potential for damage categories you have considered include temperature, gases, organisms and projectiles. The one category that you have missed is:
Question 87
Multiple Choice
A tapped trunk topology uses ________ cabling to support a DAS.
Question 88
Multiple Choice
All of the following are nominal wavelengths for laser light sources EXCEPT:
Question 89
Multiple Choice
You are placing an entrance cable between two buildings connected by a conduit 205.3 m (588 ft) in length. What would be the MAXIMUM length of unlisted OSP cable that could be used before you terminate the cable or transition it to a listed cable?
Question 90
Multiple Choice
The public telephone system is an example of a __________ system.
Question 91
Multiple Choice
Often associated with raised flooring, a(n) ________ may consist of copper straps taped to the concrete floor, or it may be the floor itself with the stringers that support the tiles acting as the bonding conductor across the gradient of the floor.
Question 92
Multiple Choice
Which of the following is true about screened twisted pair cable assemblies?
Question 93
Multiple Choice
Which is NOT true about conformance quality?
Question 94
Multiple Choice
Important considerations when designing telecommunications distribution within modular furniture include all of the following EXCEPT:
Question 95
Multiple Choice
To reduce the chance of an accidental dig-up, plastic warning tape should be placed a MINIMUM of _________ below grade, but high enough above cables to allow detection before cables are damaged.
Question 96
Multiple Choice
You have been selected to do the telecommunications design on a new, single story building. The architect requires the size and location of the telecommunications rooms so their building design can proceed. From the items listed below (all of which are required for the design) , which one is the logical starting point in order to provide the architect with a size and location for the room?
Question 97
Multiple Choice
Color codes for cross-connections fields have been used for many years. Which color is used to identify horizontal cable?
Question 98
Multiple Choice
The purpose of QoS on an IP network is for:
Question 99
Multiple Choice
The F rating for a framed wall/stud wall is ________ hour(s) .
Question 100
Multiple Choice
In an industry where a high level of humidity is measured, which type of label should be used?