Question 41
Multiple Choice
Exhibit:
A pay telephone using coins needs to be installed in a public area. In the specifications, it is required that the telephone shall meet the ADA (American with Disabilities Act) requirement for front reach using a wheelchair. What will be the maximum reachable height or the value of "X"?
Question 42
Multiple Choice
You are designing a nurse call system for an assisted care facility. What type of nurse call system would best suit the needs for the facility?
Question 43
Multiple Choice
A SONET OC-1 channel can carry 672 voice signals and has a data rate of 51.84 Mbps. A SONET OC-48 channel can carry 32,256 voice channels. What MINIMUM data rate is required for the OC-48 channel?
Question 44
Multiple Choice
Most types of firestop putty have ________ properties.
Question 45
Multiple Choice
You must place a cable between 2 equipment locations with separate grounds having a potential difference between them of 2.1 V rms. Which one of the following cables should NOT be used?
Question 46
Multiple Choice
A large telecommunications facility, by most codes, must be designed with an EPO switch located at:
Question 47
Multiple Choice
You have determined that the equipment room (ER) you are designing will be the minimum size of 15 sq m (160 sq ft) and is servicing 80 but architectural changes will add 175 , which will require you to add a horizontal cross-connect (HC) . What size should the equipment room (ER) be?
Question 48
Multiple Choice
You are designing a firestop system for a hospital with several floors that have isolation rooms. Air leakage control is important to ensure rooms are sealed and restrict the spread of disease. Which firestop test rating should you use to ensure air leakage compliance?
Question 49
Multiple Choice
Which type of cable tray is best described as a ventilated bottom with side rails?
Question 50
Multiple Choice
When a building is not on the property line, the building owner should provide a MINIMUM of ________ conduits from a point inside the building, to the property line or easement for entrance facilities.
Question 51
Multiple Choice
You are designing a 4.9 GHz microwave system that is using rectangular waveguide from the transceiver to the inside wall of the shelter and an antenna using elliptical waveguide from the antenna to the outside wall of the shelter. The antenna has been designed to be placed 200 ft up on a 250 ft tower. What device will you specify that will best interconnect the two different waveguides?
Question 52
Multiple Choice
A building can have multiple equipment rooms (ERs) for all of the following reasons EXCEPT:
Question 53
Multiple Choice
The MINIMUM finished height of access flooring in a general office area is:
Question 54
Multiple Choice
You have been asked what the estimated power cost will be per month (30 days) for the new equipment room you are designing. The power load you have calculated to be an average of 1850 watts per hour. What is the monthly cost assuming the cost of electricity is 7.5 cents (U.S.) per kilowatt hour?
Question 55
Multiple Choice
Which of the following is a nonmechanical firestop system?
Question 56
Multiple Choice
You are designing a telecommunications grounding system for a telecommunications room (TR) . The TMGB is located 15 m (50 ft) from the telecommunications rack. What is the MINIMUM AWG of the ground conductor required?
Question 57
Multiple Choice
The conversion of an analog speech signal to a pulse code modulation (PCM) digital signal involves all of the following steps EXCEPT:
Question 58
Multiple Choice
A video camera has a coaxial cable output. The video signal is to be distributed to devices that have balanced twisted pair inputs. The transition between these two different transmission media can be accomplished by using a:
Question 59
Multiple Choice
The MAXIMUM span length for an aerial entrance, from the last pole to the building, must NOT exceed:
Question 60
Multiple Choice
Which active DAS component is responsible for coupling input signals from donor systems?