Question 221
Multiple Choice
Optical fiber all-dielectric cables have an additional advantage over ones containing a steel strength member. That advantage is:
Question 222
Multiple Choice
As a guide, the recommended maximum AC current value on any bonding conductor should be less than ________ amperes.
Question 223
Multiple Choice
You must extend a video systems backbone coax cable that was recently installed. Which of the following coaxial cable types would provide the best performance for both analog and digital video?
Question 224
Multiple Choice
What is the connector of choice for Series 59, Series 6, and Series 11 applications?
Question 225
Multiple Choice
All of the following are used to control static discharge EXCEPT:
Question 226
Multiple Choice
On a project with three small conference rooms, a break room, and twelve private offices, what is the MINIMUM number of telecommunications outlet boxes required?
Question 227
Multiple Choice
An isolated ground is used to:
Question 228
Multiple Choice
Exhibit:
What does this international symbol stands for?
Question 229
Multiple Choice
Which area of project management covers the blending of various subteams into a project organization with a cohesive plan?
Question 230
Multiple Choice
In addition to voice and data services, an equipment room (ER) can be designed to include all of the following EXCEPT:
Question 231
Multiple Choice
You are designing a horizontal distribution system that will have a zone box located 71.6 m (235 ft) away from the telecommunications room (TR) . A 50 mm (2 in) conduit is designed from the TR to a pull box located 36.6 m (120 ft) away from the TR. A 1 1/2 inch conduit is designed from the pull box to the zone box located 35.1 m (115 ft) beyond the pull box. Assuming no conduit bends, and excluding the TR and zone box, what is the total number of pull boxes/pull points required in this horizontal conduit system between the telecommunications room (TR) and zone box?
Question 232
Multiple Choice
In the customer's environment, an ITS designer should avoid the need for optical fiber field splicing by:
Question 233
Multiple Choice
Which class of the system applies when the premise only has a single equipment room (ER) , and it is the only telecommunications space administered?
Question 234
Multiple Choice
You are working on the design of a new, large ER/TR that will contain many racks and data cabinets including a large UPS system. Your recommendation to the architect for room access from inside the building is:
Question 235
Multiple Choice
Data representation including code translations, compressions, and encryptions is performed by what layer of the OSI model?
Question 236
Multiple Choice
If looking to specify an optical fiber backbone within a building going 275 m (902 ft) between the equipment room (ER) and the telecommunications room (TR) , what type of fiber should be specified to support a 10 GB ethernet application?
Question 237
Multiple Choice
"A single outlet utilizing a dedicated phase, neutral, and ground conductor" is the definition for which of the following?
Question 238
Multiple Choice
Which of the following is NOT a type of connector for optical fiber?
Question 239
Multiple Choice
Which device supplies the radio signal into a DAS (distributive antenna system) ?
Question 240
Multiple Choice
You have been asked to provide a UPS that is always serving the load from its batteries and the electrical supply is used only to recharge the batteries. Which one of the following types of UPS will meet this requirement?