Exam 14: Lamps and Ballasts for Lighting
Exam 1: Commercial Building Plans and Specifications20 Questions
Exam 2: Reading Electrical Working Drawings--Entry Level20 Questions
Exam 3: General Requirements for Conductors16 Questions
Exam 4: Branch Circuits20 Questions
Exam 5: Switches and Receptacles20 Questions
Exam 6: Wiring Methods20 Questions
Exam 7: Motor and Appliance Circuits20 Questions
Exam 8: Feeder Installation and Load Calculation22 Questions
Exam 9: Special Systems20 Questions
Exam 10: Working Drawings--Upper Level20 Questions
Exam 11: Special Circuits Owners Circuits20 Questions
Exam 12: Panelboard Selection and Installation20 Questions
Exam 13: The Electric Service and Grounding20 Questions
Exam 14: Lamps and Ballasts for Lighting20 Questions
Exam 15: Luminaires20 Questions
Exam 16: Emergency, Legally Required Standby, and Optional Standby Power Systems20 Questions
Exam 17: Overcurrent Protection: Fuses and Circuit Breakers20 Questions
Exam 18: Short-Circuit Calculations and Coordination of Overcurrent Protective Devices20 Questions
Exam 19: Equipment and Conductor Short-Circuit17 Questions
Exam 20: Low-Voltage Remote Control20 Questions
Exam 21: The Cooling System20 Questions
Exam 22: Commercial Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
What are the advantages of proper bonding and grounding?
Free
(Essay)
4.9/5
(93)
Correct Answer:
The advantages of proper bonding and grounding include:
∙ The potential voltage differentials between the different parts of the system are kept at a minimum, thereby reducing shock hazard.
∙ Impedance of a ground path is kept at a minimum, which results in higher current flow in the event of a ground fault. The lower the impedance, the greater is the current flow, and the faster the overcurrent device opens.
NEC 230.71 permits not more than ____ disconnects to serve as the building disconnecting means.
Free
(Multiple Choice)
4.8/5
(83)
Correct Answer:
A
The lower (or shorter)the ____ of the grounding path, the greater the ground-fault current.
Free
(Multiple Choice)
5.0/5
(61)
Correct Answer:
D
Today's liquid-filled transformers have their windings immersed in highly refined mineral oil (combustible), silicone fluid, edible seed oil-based dielectric coolant, or other acceptable nontoxic liquids that have ____ properties.
(Multiple Choice)
4.8/5
(64)
____ occur when an ungrounded "hot" conductor comes in contact with a grounded surface or grounded equipment.
(Multiple Choice)
4.8/5
(78)
The temperatures of an electrical arc, such as might occur on a 480/277-volt solidly grounded, wye-connected system, are ____.
(Multiple Choice)
4.8/5
(97)
In this country and throughout the world, ____ is(are)the common reference point for all electrical systems.
(Multiple Choice)
4.8/5
(86)
The ____ is defined in NEC Article 100 as the point of connection between the facilities of the serving utility and the premises wiring .
(Multiple Choice)
4.8/5
(82)
NEC 110.16 has a requirement for placing a notice on certain equipment to warn qualified persons of the serious hazard of ____ flash events.
(Multiple Choice)
4.7/5
(83)
Utilities make up the connections on the line side and load side of their transformers according to the ____ requirements.
(Multiple Choice)
4.9/5
(84)
What liquid was used in the past in liquid-filled transformers? Is it still in use?
(Essay)
4.7/5
(77)
Dry-type transformers are widely used because they are ____ than comparably rated liquid-filled transformers.
(Multiple Choice)
4.8/5
(67)
The ____ connection scheme has the advantage of being able to provide either 3-phase or 3-phase and single-phase power using only two transformers.
(Multiple Choice)
4.9/5
(84)
The two basic methods of metering are primary high-voltage metering and ____.
(Multiple Choice)
4.9/5
(76)
NEC 250.64(C)states that grounding electrode conductors generally are not permitted to be ____.
(Multiple Choice)
4.9/5
(77)
GFCI protection can be attained using GFCI circuit breakers or GFCI ____.
(Multiple Choice)
5.0/5
(85)