Exam 6: Wiring Methods
Exam 1: Commercial Building Plans and Specifications20 Questions
Exam 2: Reading Electrical Working Drawings--Entry Level20 Questions
Exam 3: General Requirements for Conductors16 Questions
Exam 4: Branch Circuits20 Questions
Exam 5: Switches and Receptacles20 Questions
Exam 6: Wiring Methods20 Questions
Exam 7: Motor and Appliance Circuits20 Questions
Exam 8: Feeder Installation and Load Calculation22 Questions
Exam 9: Special Systems20 Questions
Exam 10: Working Drawings--Upper Level20 Questions
Exam 11: Special Circuits Owners Circuits20 Questions
Exam 12: Panelboard Selection and Installation20 Questions
Exam 13: The Electric Service and Grounding20 Questions
Exam 14: Lamps and Ballasts for Lighting20 Questions
Exam 15: Luminaires20 Questions
Exam 16: Emergency, Legally Required Standby, and Optional Standby Power Systems20 Questions
Exam 17: Overcurrent Protection: Fuses and Circuit Breakers20 Questions
Exam 18: Short-Circuit Calculations and Coordination of Overcurrent Protective Devices20 Questions
Exam 19: Equipment and Conductor Short-Circuit17 Questions
Exam 20: Low-Voltage Remote Control20 Questions
Exam 21: The Cooling System20 Questions
Exam 22: Commercial Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
A(n)____ box is used for surface or concealed installations.
Free
(Multiple Choice)
4.8/5
(83)
Correct Answer:
A
The two most popular types of PVC are Schedule 40 and Schedule ____.
Free
(Multiple Choice)
4.9/5
(76)
Correct Answer:
D
____ is a thin-wall metal raceway that is not permitted to be threaded.
Free
(Multiple Choice)
4.8/5
(94)
Correct Answer:
C
Of what must you be especially careful regarding the depth of the box you are using?
(Essay)
4.9/5
(71)
Where PVC conduit is connected to a box or enclosure, a ____ is recommended.
(Multiple Choice)
4.9/5
(86)
Flexible metal and nonmetallic conduit are commonly used to connect recessed or lay-in ____. When used in this manner, electricians refer to it as a "fixture whip."
(Multiple Choice)
4.7/5
(82)
Liquidtight flexible nonmetallic conduit marked as ____ has a smooth seamless inner core and cover bonded together and one or more reinforcement layers between the core and covers for layered conduit .
(Multiple Choice)
4.9/5
(75)
When pulling three conductors or cables into a raceway, if the ratio of the raceway diameter to the conductor diameter is between 2.8 and 3.2, jamming can occur. With ____ or more conductors or cables, jamming is highly unlikely.
(Multiple Choice)
4.8/5
(94)
Type MC cable is a factory assembly of one or more insulated circuit conductors with or without optical fiber members enclosed in an armor of ____ metal tape, or a smooth or corrugated metallic sheath.
(Multiple Choice)
4.9/5
(78)
Voltage drop in a circuit is calculated by multiplying the current flow times the ____.
(Multiple Choice)
4.8/5
(76)
Compression fittings for EMT are classified as raintight and ____-tight types.
(Multiple Choice)
4.8/5
(70)
When a box contains fittings such as luminaire studs, clamps, or hickeys, the number of conductors permitted in the box is one less for ____ device.
(Multiple Choice)
4.8/5
(86)
Conduit bodies are often referred to in the trade as "Condulets" and "____."
(Multiple Choice)
4.7/5
(78)
On what factors do the conduit and tubing size required for an installation depend?
(Essay)
4.9/5
(69)
The term ____ is defined by the NEC as a channel that is designed expressly for holding wires, cables, or busbars.
(Multiple Choice)
4.9/5
(74)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)