Exam 5: Switches and Receptacles
Exam 1: Commercial Building Plans and Specifications20 Questions
Exam 2: Reading Electrical Working Drawings--Entry Level20 Questions
Exam 3: General Requirements for Conductors16 Questions
Exam 4: Branch Circuits20 Questions
Exam 5: Switches and Receptacles20 Questions
Exam 6: Wiring Methods20 Questions
Exam 7: Motor and Appliance Circuits20 Questions
Exam 8: Feeder Installation and Load Calculation22 Questions
Exam 9: Special Systems20 Questions
Exam 10: Working Drawings--Upper Level20 Questions
Exam 11: Special Circuits Owners Circuits20 Questions
Exam 12: Panelboard Selection and Installation20 Questions
Exam 13: The Electric Service and Grounding20 Questions
Exam 14: Lamps and Ballasts for Lighting20 Questions
Exam 15: Luminaires20 Questions
Exam 16: Emergency, Legally Required Standby, and Optional Standby Power Systems20 Questions
Exam 17: Overcurrent Protection: Fuses and Circuit Breakers20 Questions
Exam 18: Short-Circuit Calculations and Coordination of Overcurrent Protective Devices20 Questions
Exam 19: Equipment and Conductor Short-Circuit17 Questions
Exam 20: Low-Voltage Remote Control20 Questions
Exam 21: The Cooling System20 Questions
Exam 22: Commercial Utility-Interactive Photovoltaic Systems20 Questions
Select questions type
When the wiring method is cable, you are stuck with the conductor insulation colors typically provided by the manufacturer. For three conductor cable, this will typically be black, white, and ____.
Free
(Multiple Choice)
4.8/5
(78)
Correct Answer:
A
Isolated ground receptacles are required by NEC 406.3(D) to have a(n)____ triangle on their face.
Free
(Multiple Choice)
4.8/5
(89)
Correct Answer:
A
An acceptable impedance for the grounding path associated with normal equipment grounding for branch-circuit wiring is ____ ohms.
Free
(Multiple Choice)
5.0/5
(80)
Correct Answer:
A
A ____ switch is used where it is desired to control a light or group of lights, or other load, from one switching point.
(Multiple Choice)
4.9/5
(77)
The differences in plugs and receptacles are based on the ____ and voltage rating of the device.
(Multiple Choice)
4.8/5
(83)
Quality voltage provides a clean ____ wave that is free from distortion.
(Multiple Choice)
4.7/5
(78)
To reduce "electrical noise" (electromagnetic interference), circuits with receptacle outlets that serve loads such as cash registers, computers, or other sensitive electronic equipment are often supplied by ____ receptacles.
(Multiple Choice)
4.9/5
(79)
A 3-way switch has a common terminal to which the switch blade is always connected, and it has two other terminals called ____ terminals.
(Multiple Choice)
4.9/5
(88)
Most electricians refer to ____ switches as "toggle switches" or "wall switches."
(Multiple Choice)
4.9/5
(75)
When using cable for the wiring of 3-way switches, NEC 200.7(C)(1)permits the use of a conductor with insulation that is white or ____ or has three continuous white stripes (not too common)as a switch supply only if the conductor is permanently reidentified by painting or other effective means.
(Multiple Choice)
4.7/5
(65)
The cover placed on a recessed box containing a receptacle or a switch is called a ____.
(Multiple Choice)
4.8/5
(74)
In locations where severe abuse or heavy use is expected, ____ receptacles are recommended.
(Multiple Choice)
4.8/5
(71)
What is the difference between the acceptable impedance of a ground path for branch-circuit wiring and the acceptable impedance for electronic equipment?
(Essay)
4.7/5
(81)
An ac-dc general-use snap switch is always marked with the ____.
(Multiple Choice)
4.8/5
(70)
In commercial buildings, ____ protection is required for all 125-volt through 250-volt , single-phase 50-ampere receptacles or less, and three-phase 100 amperes or less, installed in bathrooms, in kitchens, on rooftops, outdoors, within 6 ft (1.8 m)from the outside edge of any sink, in indoor damp and wet locations, in locker rooms with associated shower facilities, garages, accessory buildings, service bays, and similar areas , crawl spaces, unfinished areas of basements, laundry areas, and bathtubs and shower stalls.
(Multiple Choice)
5.0/5
(71)
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)