Exam 6: Special Purpose Motor, Control Devices and Programmable Logic Controllers

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

In Ethernet/IP the IP stands for international protocol.

(True/False)
4.9/5
(85)

Select the correct input logic contact for the following situation. Field device is NC, the rung output should be on or active when the field device is not activated.

(Multiple Choice)
5.0/5
(83)

Match the advantage to its encoder. -Uses a reference starting point

(Multiple Choice)
5.0/5
(76)

A valve stack would be a likely device connected to ControlNet but another PLC is usually never connected to ControlNet.

(True/False)
4.9/5
(82)

In single -phase operation of a resolver, one of the stator windings is shorted.

(True/False)
4.9/5
(85)

Match the SLC 500 TON timer input and output condition with the correct description of timer operation. -Timer enable bit

(Multiple Choice)
4.8/5
(74)

The TOF timer for SLC 500 PLC turns the done bit off when the accumulator reaches the preset value.

(True/False)
4.8/5
(88)

If the contact on a PLC ladder logic rung is an examine off type, then

(Multiple Choice)
4.8/5
(82)

Match the benefit to its motor . -Has an electronic commutator

(Multiple Choice)
4.9/5
(64)

Match the Allen Bradley SLC 500 register symbol with the register function. -R6

(Multiple Choice)
4.9/5
(74)

In the Allen Bradley RS Logix PLC all variables are called tags.

(True/False)
4.7/5
(79)

Match the advantage to its encoder. -Generally a lower cost device

(Multiple Choice)
4.9/5
(90)

ControlNet uses the product/consummer model, is highly deterministic and repeatable, and is ideal for interfacing with smart sensors.

(True/False)
4.8/5
(86)

The best PLC language for programming the operation of a machine with many distinct steps in the operation is

(Multiple Choice)
4.7/5
(85)

A three -phase variable reluctance stepper motor with twelve stator windings has the windings set thirty degrees apart.

(True/False)
4.7/5
(69)

The two -phase operation of a resolver uses the variation in voltage amplitude to determine shaft position.

(True/False)
4.7/5
(67)

The servo motor controller has replaced the servo amplifier for most applications.

(True/False)
4.8/5
(60)

One advantage of the variable reluctance stepper motor is that it has much more holding torque than permanent magnetic stepper motor.

(True/False)
4.7/5
(70)

In a stepper motor, only one stator winding is energized at a time as the north pole.

(True/False)
4.9/5
(86)

Function block diagram PLC programs execute by inputting all input variable values and then evaluating the blocks starting with the blocks on the far right.

(True/False)
4.9/5
(79)
Showing 61 - 80 of 125
close modal

Filters

  • Essay(0)
  • Multiple Choice(0)
  • Short Answer(0)
  • True False(0)
  • Matching(0)