Exam 6: Special Purpose Motor, Control Devices and Programmable Logic Controllers
Exam 1: Introduction to Industrial Control Systems, Discrete Control Input and Output Devices105 Questions
Exam 2: Solidstate Devices in Industrial Applications, Operational Amplifiers and Linear ICS79 Questions
Exam 3: SCRS, Triacs, Other Thryristors, Discrete Automation Sensors and Devices100 Questions
Exam 4: Analog Processes Control Devices, Sensors and Safety102 Questions
Exam 5: DC Motors, Control Circuits, AC Motors and Variable Speed Drives89 Questions
Exam 6: Special Purpose Motor, Control Devices and Programmable Logic Controllers125 Questions
Exam 7: Embedded Microcontrollers, Open and Closed Loop Process Control130 Questions
Exam 8: Industrial Robots, Automation Systems and Data Communication Between Intelligent Machines115 Questions
Select questions type
The permanent magnetics of the conventional PM motor are magnetized along their length or their width.
(True/False)
4.8/5
(78)
Match the benefit to its motor .
-Responds quickly to change in input voltage
(Multiple Choice)
4.8/5
(78)
The done bit of a CTD counter in an SLC 500 PLC turs on when the accumulator counts up to the preset value.
(True/False)
4.9/5
(73)
Sequential function charts is a PLC langauge that is much like Grafcet.
(True/False)
5.0/5
(82)
Select the correct input logic contact for the following situation. Field device is NC, the rung output should be off or not active when the field device is not activated.
(Multiple Choice)
4.9/5
(69)
PLCs introduced in the future will have variable -based addressing for variables and not rack/slot addressing.
(True/False)
4.8/5
(77)
The PLC language that is most like assembly language in a microprocessor is
(Multiple Choice)
4.8/5
(93)
Match the benefit to its motor .
-Responds quickly to changes in speed
(Multiple Choice)
5.0/5
(91)
Which of the following is not an advantage of a permanent magnetic motor over a field wound motor?
(Multiple Choice)
4.9/5
(73)
Which of the following bits is NOT found in an SLC 500 counter command?
(Multiple Choice)
4.7/5
(91)
Select the correct input logic contact for the following situation. Field device is NO, the rung output should be on or active when the field device is activated.
(Multiple Choice)
4.9/5
(71)
Match the advantage to its encoder.
-Does not lose information because of a power dropout
(Multiple Choice)
4.9/5
(90)
The determination of the direction of rotation by an optical encoder is independent of the number of tracks.
(True/False)
4.8/5
(62)
The inability of stepper motors to follow the step command exactly results in damping followed by oscillations.
(True/False)
4.8/5
(90)
Showing 41 - 60 of 125