Exam 7: Embedded Microcontrollers, Open and Closed Loop Process Control
Exam 1: Introduction to Industrial Control Systems, Discrete Control Input and Output Devices105 Questions
Exam 2: Solidstate Devices in Industrial Applications, Operational Amplifiers and Linear ICS79 Questions
Exam 3: SCRS, Triacs, Other Thryristors, Discrete Automation Sensors and Devices100 Questions
Exam 4: Analog Processes Control Devices, Sensors and Safety102 Questions
Exam 5: DC Motors, Control Circuits, AC Motors and Variable Speed Drives89 Questions
Exam 6: Special Purpose Motor, Control Devices and Programmable Logic Controllers125 Questions
Exam 7: Embedded Microcontrollers, Open and Closed Loop Process Control130 Questions
Exam 8: Industrial Robots, Automation Systems and Data Communication Between Intelligent Machines115 Questions
Select questions type
MATCHING. Choose the item in column 2 that best matches each item in column 1.
Match the process control term with the correct definition of the term. Definitions may be used more than once.
-Set point
(Multiple Choice)
4.9/5
(87)
MATCHING. Choose the item in column 2 that best matches each item in column 1.
Match the process control term with the correct definition of the term. Definitions may be used more than once.
-Reference
(Multiple Choice)
4.9/5
(94)
Floating control has three output levels of 0, 50, and 100 percent.
(True/False)
4.9/5
(94)
The system response is the change in the system output when a known stimulus, such as a step function, is applied to the system input.
(True/False)
4.7/5
(78)
Derivative action in a controller causes the final control element to change rapidly with rapid changes in the error.
(True/False)
4.8/5
(73)
The peak gain on the closed loop Bode response for a second order lag system should be between 8 and 10 db.
(True/False)
4.8/5
(77)
One difference between digital controller and analog controllers is that analog controllers produce an output almost instantly, while the digital output is based on the sampling rate.
(True/False)
4.8/5
(91)
Steady state error is the value of the error signal or the offset in the process variable after the control system has responded to a change and settled down to its final value.
(True/False)
4.9/5
(70)
Both synchronous and asynchronous ports provide serial I/O for the microcontroller.
(True/False)
4.9/5
(84)
A bias value can be used to correct for steady -state error, but the bias value must be changed whenever the set point is changed or a new disturbance is present.
(True/False)
4.9/5
(84)
MATCHING. Choose the item in column 2 that best matches each item in column 1.
Match the process control term with the correct definition of the term. Definitions may be used more than once.
-Manipulated variable
(Multiple Choice)
4.9/5
(94)
In cascade and feedforward control the control systems uses two closed -loop systems to correct for system disturbances.
(True/False)
4.8/5
(82)
Which one of the following is NOT one of the advantages that control systems offer?
(Multiple Choice)
4.8/5
(75)
A process load change is a change in the process environment that causes the process to move away from the set point value.
(True/False)
4.9/5
(84)
The integral time for an integral controller is the time required for the integral controller output to match the change produced by the proportional controller output.
(True/False)
4.7/5
(80)
The error equation for a direct acting closed loop system is E=SP -PV.
(True/False)
4.8/5
(88)
A system model is a mathematic description of the system that generates the same transient and steady -state output response to a known input stimulus as the actual system.
(True/False)
4.8/5
(74)
Showing 21 - 40 of 130