Exam 3: Boxes and Enclosures
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services Feeders and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies26 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Box calculations for 4 AWG and larger conductors (1000 volts or less) are performed based on the ____.
Free
(Multiple Choice)
4.7/5
(75)
Correct Answer:
B
Cable connector(s) with a ____ outside the box are not counted when determining the number of conductors.
Free
(Multiple Choice)
4.9/5
(80)
Correct Answer:
C
The weight supported by any single conduit shall not exceed ____.
Free
(Multiple Choice)
5.0/5
(75)
Correct Answer:
B
What is the angle pull for a raceway in the horizontal dimension where the trade size of the largest raceway is 3 in.and the sum of the other raceways in the same row on the same wall is 4 in.?
(Multiple Choice)
4.8/5
(82)
Wire connectors, pigtails, locknuts, bushings, raceway connectors, and grounding screws are not factors when calculating ____.
(Multiple Choice)
5.0/5
(75)
The maximum number of conductors applies only if the box does not contain any ____.
(Multiple Choice)
4.8/5
(83)
Equipment grounding conductor(s) or equipment bonding jumpers entering a box count as ____ unless there are more than four equipment grounding conductors.
(Multiple Choice)
4.9/5
(87)
____ or fewer luminaire wires (smaller than 14 AWG) and an equipment grounding conductor can be omitted from box fill calculations if they enter a box from a domed luminaire (or similar canopy) and terminate within that box.
(Multiple Choice)
4.9/5
(74)
Nonmetallic-sheathed cable not fastened to the box must be secured within ____ of the box.
(Multiple Choice)
4.8/5
(75)
What is the angle pull for a raceway in the vertical dimension where the trade size of the largest raceway is 4 in.and the sum of the other raceways in the same row on the same wall is 5 in.?
(Multiple Choice)
4.8/5
(92)
Snap switches (including dimmer switches) must be connected to a(n) ____ and must also provide a means to connect metal faceplates to the equipment grounding conductor, even if a metal faceplate is not installed.
(Multiple Choice)
4.8/5
(74)
Volume shall be marked on all nonmetallic boxes and boxes with a volume of ____ or less.
(Multiple Choice)
4.9/5
(85)
Inspection of the connections between luminaire conductors and circuit conductors must be possible without ____.
(Multiple Choice)
4.8/5
(83)
The length of a straight pull for multiple raceways must be at least ____ times the trade size (metric designator) of the largest single raceway.
(Multiple Choice)
4.9/5
(93)
No requirement specifies the depth of a box, unless a ____.
(Multiple Choice)
4.8/5
(95)
Where multiple rows of raceways enter a box, you should calculate each row separately and use the ____.
(Multiple Choice)
4.9/5
(83)
Multiconductor cord or cable used to support a box must be protected in an approved manner so that the conductors are not subjected to ____.
(Multiple Choice)
5.0/5
(99)
A 3- x 2-in.(75- x 50-mm) device box, 2.5 in.(65 mm) deep, has a volume of ____.
(Multiple Choice)
4.9/5
(77)
Showing 1 - 20 of 25
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)