Exam 17: Industrial Locations
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services Feeders and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies26 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Where multiple power supplies serve the same dc system, the dc side of each power supply shall have a ____.
Free
(Multiple Choice)
4.8/5
(78)
Correct Answer:
A
Cartridge fuse and fuseholder overcurrent protection provisions are located in ____.
Free
(Multiple Choice)
4.7/5
(84)
Correct Answer:
C
The tap conductor's ampacity shall not be less than the ____ on the circuits it supplies.
Free
(Multiple Choice)
4.7/5
(80)
Correct Answer:
B
Motor circuits rated 1000 volts, nominal, or less, shall have a disconnecting means with an ampere rating of at least ____% of the motor's full-load current rating.
(Multiple Choice)
4.8/5
(83)
To calculate the ampacity of conductors supplying several motors (feeder conductors), multiply the largest motor full-load current (FLC) rating by ____% and add the FLC ratings of all other motors (or loads) in the group.
(Multiple Choice)
4.8/5
(93)
A tap conductor is a ____ that exceeds the value permitted for similar conductors protected as otherwise described in 240.4.
(Multiple Choice)
4.8/5
(95)
The combined length of one primary plus one secondary conductor (excluding any portion of the primary conductor protected at its ampacity) shall not exceed ____.
(Multiple Choice)
4.9/5
(83)
The capacitor circuit conductor's ampacity shall be at least ____% of the capacitor's rated current.
(Multiple Choice)
4.8/5
(82)
If a single raceway or cable tray is used to supply the equipment, only one ____ is required.
(Multiple Choice)
4.8/5
(73)
If the ungrounded supply conductors are larger than 1100 kcmil copper or 1750 kcmil aluminum, the supply-side bonding jumper shall have an area not less than ____ percent of the area of the largest ungrounded supply conductor or equivalent area for parallel supply conductors.
(Multiple Choice)
4.9/5
(92)
____ branch circuits shall be protected at the motor nameplate current rating.
(Multiple Choice)
4.9/5
(82)
Where an orderly shutdown is required to minimize the personnel/equipment hazard(s), a system of coordination based on the following two conditions is permitted: (1) coordinated short-circuit protection and (2) ____.
(Multiple Choice)
4.8/5
(81)
Means shall be provided to disconnect all conductors in a building (or other structure) from the ____.
(Multiple Choice)
4.8/5
(92)
A transformer's primary conductors shall have an ampacity at least ____ of the feeder conductors' overcurrent device rating.
(Multiple Choice)
4.8/5
(78)
Knife switches rated more than ____, and at over 1000 amperes at 251 to 1000 volts, shall be used only as isolating switches and shall not be opened under load.
(Multiple Choice)
4.9/5
(76)
Overload is defined as operation of equipment in excess of normal, full-load rating, or of a conductor ____ that, when it persists for a sufficient length of time, would cause damage or dangerous overheating.
(Multiple Choice)
4.7/5
(90)
For the 10-ft feeder tap rule, a 60-ampere rated conductor is the minimum size allowed if the overcurrent protection on the tap conductor's line side is ____.
(Multiple Choice)
4.7/5
(85)
If a crane, hoist, or monorail hoist operates above readily combustible material, specific requirements shall apply to ____.
(Multiple Choice)
4.9/5
(75)
Wherever such an arrangement is practicable, transformer vaults shall be located so that ____.
(Multiple Choice)
4.8/5
(71)
Showing 1 - 20 of 25
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)