Where multiple power supplies serve the same dc system, the dc side of each power supply shall have a ____.

Free
(Multiple Choice)
4.8/5
(78)
Correct Answer:
Verified

A

Cartridge fuse and fuseholder overcurrent protection provisions are located in ____.

Free
(Multiple Choice)
4.7/5
(84)
Correct Answer:
Verified

C

The tap conductor's ampacity shall not be less than the ____ on the circuits it supplies.

Free
(Multiple Choice)
4.7/5
(80)
Correct Answer:
Verified

B

Motor circuits rated 1000 volts, nominal, or less, shall have a disconnecting means with an ampere rating of at least ____% of the motor's full-load current rating.

(Multiple Choice)
4.8/5
(83)

To calculate the ampacity of conductors supplying several motors (feeder conductors), multiply the largest motor full-load current (FLC) rating by ____% and add the FLC ratings of all other motors (or loads) in the group.

(Multiple Choice)
4.8/5
(93)

A tap conductor is a ____ that exceeds the value permitted for similar conductors protected as otherwise described in 240.4.

(Multiple Choice)
4.8/5
(95)

The combined length of one primary plus one secondary conductor (excluding any portion of the primary conductor protected at its ampacity) shall not exceed ____.

(Multiple Choice)
4.9/5
(83)

The capacitor circuit conductor's ampacity shall be at least ____% of the capacitor's rated current.

(Multiple Choice)
4.8/5
(82)

If a single raceway or cable tray is used to supply the equipment, only one ____ is required.

(Multiple Choice)
4.8/5
(73)

A transformer vault door must be ____.

(Multiple Choice)
4.8/5
(70)

If the ungrounded supply conductors are larger than 1100 kcmil copper or 1750 kcmil aluminum, the supply-side bonding jumper shall have an area not less than ____ percent of the area of the largest ungrounded supply conductor or equivalent area for parallel supply conductors.

(Multiple Choice)
4.9/5
(92)

____ branch circuits shall be protected at the motor nameplate current rating.

(Multiple Choice)
4.9/5
(82)

Where an orderly shutdown is required to minimize the personnel/equipment hazard(s), a system of coordination based on the following two conditions is permitted: (1) coordinated short-circuit protection and (2) ____.

(Multiple Choice)
4.8/5
(81)

Means shall be provided to disconnect all conductors in a building (or other structure) from the ____.

(Multiple Choice)
4.8/5
(92)

A transformer's primary conductors shall have an ampacity at least ____ of the feeder conductors' overcurrent device rating.

(Multiple Choice)
4.8/5
(78)

Knife switches rated more than ____, and at over 1000 amperes at 251 to 1000 volts, shall be used only as isolating switches and shall not be opened under load.

(Multiple Choice)
4.9/5
(76)

Overload is defined as operation of equipment in excess of normal, full-load rating, or of a conductor ____ that, when it persists for a sufficient length of time, would cause damage or dangerous overheating.

(Multiple Choice)
4.7/5
(90)

For the 10-ft feeder tap rule, a 60-ampere rated conductor is the minimum size allowed if the overcurrent protection on the tap conductor's line side is ____.

(Multiple Choice)
4.7/5
(85)

If a crane, hoist, or monorail hoist operates above readily combustible material, specific requirements shall apply to ____.

(Multiple Choice)
4.9/5
(75)

Wherever such an arrangement is practicable, transformer vaults shall be located so that ____.

(Multiple Choice)
4.8/5
(71)