Exam 9: Services and Electrical Equipment

arrow
  • Select Tags
search iconSearch Question
  • Select Tags

Splices in wire-type grounding electrode conductors are acceptable only if by means of irreversible compression-type connectors (listed as grounding and bonding equipment) or by the ____.

Free
(Multiple Choice)
4.9/5
(96)
Correct Answer:
Verified

B

Concrete, brick, or tile walls are recognized as ____.

Free
(Multiple Choice)
4.9/5
(70)
Correct Answer:
Verified

B

Panelboards shall be mounted in cabinets, cutout boxes, or identified enclosures and shall be ____.

Free
(Multiple Choice)
4.9/5
(94)
Correct Answer:
Verified

C

Main bonding jumpers and system bonding jumpers must be made of ____ or other corrosion-resistant material.

(Multiple Choice)
4.7/5
(76)

Wireways are ____ with hinged or removable covers used to house and protect electric wires and cables.

(Multiple Choice)
4.9/5
(90)

The ampere rating of any circuit breaker rated at ____ amperes or less, and 1000 volts or less, must be molded, stamped, etched, or similarly marked into the handle or escutcheon area.

(Multiple Choice)
4.8/5
(62)

Overhead service conductors, accessible only to pedestrian traffic, must have a minimum ____ vertical clearance above finished grade, sidewalks, platforms, or projections that will permit personal contact.

(Multiple Choice)
4.8/5
(78)

Voltage between overhead conductors does not exceed ____ volts.

(Multiple Choice)
4.7/5
(61)

The radius of the curve of the inner edge of any bend in service-entrance cable must be at least ____ times the diameter of the cable.

(Multiple Choice)
4.9/5
(83)

Service-entrance and overhead service conductors shall be arranged so that ____.

(Multiple Choice)
4.9/5
(72)

Conductor sizes are expressed in American Wire Gage (AWG) or in ____.

(Multiple Choice)
4.8/5
(68)

A one-family dwelling service disconnecting means must have a minimum rating of ____.

(Multiple Choice)
4.9/5
(83)

Fuses must be plainly marked (by printing on or a label attached to the fuse barrel), showing the following: (1) ampere rating, (2) voltage rating, (3) ____, (4) "current-limiting" where applicable, and (5) the name or trademark of the manufacturer.

(Multiple Choice)
4.8/5
(71)

Fuseholders for current-limiting fuses must not ____.

(Multiple Choice)
4.7/5
(81)

Cartridge fuses and fuseholders are classified according to ____.

(Multiple Choice)
4.8/5
(82)

Conductors must have a vertical clearance of at least ____ above the roof surface.

(Multiple Choice)
4.8/5
(65)

Panelboards include overcurrent devices as well as ____.

(Multiple Choice)
4.8/5
(93)

Underground service conductors are defined as the underground conductors between the service point and the ____ to the service-entrance conductors in a terminal box, meter, or other enclosure, inside or outside the building wall.

(Multiple Choice)
4.9/5
(79)

Although not stipulated in the NEC , some local jurisdictions have adopted ____ for service conductors.

(Multiple Choice)
4.8/5
(78)

Entrance cables must be supported within ____ of every raceway or enclosure connection.

(Multiple Choice)
4.7/5
(60)
Showing 1 - 20 of 27