Exam 9: Services and Electrical Equipment
Exam 1: Introduction to the National Electrical Code13 Questions
Exam 2: Definitions25 Questions
Exam 3: Boxes and Enclosures25 Questions
Exam 4: Cables17 Questions
Exam 5: Raceways and Conductors26 Questions
Exam 6: General Provisions25 Questions
Exam 7: Specific Provisions25 Questions
Exam 8: Load Calculations25 Questions
Exam 9: Services and Electrical Equipment27 Questions
Exam 10: Comprehensive Provisions25 Questions
Exam 11: Load Calculations14 Questions
Exam 12: General Provisions25 Questions
Exam 13: Nondwelling Load Calculations17 Questions
Exam 14: Services Feeders and Equipment25 Questions
Exam 15: Hazardous Classified Locations25 Questions
Exam 16: Health Care25 Questions
Exam 17: Industrial Locations25 Questions
Exam 18: Special Occupancies26 Questions
Exam 19: Specific Equipment25 Questions
Select questions type
Splices in wire-type grounding electrode conductors are acceptable only if by means of irreversible compression-type connectors (listed as grounding and bonding equipment) or by the ____.
Free
(Multiple Choice)
4.9/5
(96)
Correct Answer:
B
Concrete, brick, or tile walls are recognized as ____.
Free
(Multiple Choice)
4.9/5
(70)
Correct Answer:
B
Panelboards shall be mounted in cabinets, cutout boxes, or identified enclosures and shall be ____.
Free
(Multiple Choice)
4.9/5
(94)
Correct Answer:
C
Main bonding jumpers and system bonding jumpers must be made of ____ or other corrosion-resistant material.
(Multiple Choice)
4.7/5
(76)
Wireways are ____ with hinged or removable covers used to house and protect electric wires and cables.
(Multiple Choice)
4.9/5
(90)
The ampere rating of any circuit breaker rated at ____ amperes or less, and 1000 volts or less, must be molded, stamped, etched, or similarly marked into the handle or escutcheon area.
(Multiple Choice)
4.8/5
(62)
Overhead service conductors, accessible only to pedestrian traffic, must have a minimum ____ vertical clearance above finished grade, sidewalks, platforms, or projections that will permit personal contact.
(Multiple Choice)
4.8/5
(78)
Voltage between overhead conductors does not exceed ____ volts.
(Multiple Choice)
4.7/5
(61)
The radius of the curve of the inner edge of any bend in service-entrance cable must be at least ____ times the diameter of the cable.
(Multiple Choice)
4.9/5
(83)
Service-entrance and overhead service conductors shall be arranged so that ____.
(Multiple Choice)
4.9/5
(72)
Conductor sizes are expressed in American Wire Gage (AWG) or in ____.
(Multiple Choice)
4.8/5
(68)
A one-family dwelling service disconnecting means must have a minimum rating of ____.
(Multiple Choice)
4.9/5
(83)
Fuses must be plainly marked (by printing on or a label attached to the fuse barrel), showing the following: (1) ampere rating, (2) voltage rating, (3) ____, (4) "current-limiting" where applicable, and (5) the name or trademark of the manufacturer.
(Multiple Choice)
4.8/5
(71)
Cartridge fuses and fuseholders are classified according to ____.
(Multiple Choice)
4.8/5
(82)
Conductors must have a vertical clearance of at least ____ above the roof surface.
(Multiple Choice)
4.8/5
(65)
Underground service conductors are defined as the underground conductors between the service point and the ____ to the service-entrance conductors in a terminal box, meter, or other enclosure, inside or outside the building wall.
(Multiple Choice)
4.9/5
(79)
Although not stipulated in the NEC , some local jurisdictions have adopted ____ for service conductors.
(Multiple Choice)
4.8/5
(78)
Entrance cables must be supported within ____ of every raceway or enclosure connection.
(Multiple Choice)
4.7/5
(60)
Showing 1 - 20 of 27
Filters
- Essay(0)
- Multiple Choice(0)
- Short Answer(0)
- True False(0)
- Matching(0)